A review on the finite element simulation of fretting wear and corrosion in the taper junction of hip replacement implants
Published 2020 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
A review on the finite element simulation of fretting wear and corrosion in the taper junction of hip replacement implants
Authors
Keywords
Taperosis, Fretting wear, Finite element analysis, Taper junction, Hip implants
Journal
COMPUTERS IN BIOLOGY AND MEDICINE
Volume -, Issue -, Pages 104196
Publisher
Elsevier BV
Online
2020-12-23
DOI
10.1016/j.compbiomed.2020.104196
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Adaptive finite element simulation of fretting wear and fatigue in a taper junction of modular hip prosthesis
- (2020) Ali Cherif Messellek et al. Journal of the Mechanical Behavior of Biomedical Materials
- Does Taper Design Affect Taper Fretting Corrosion in Ceramic-on-Polyethylene Total Hip Arthroplasty? A Retrieval Analysis
- (2019) Matthew P. Siljander et al. JOURNAL OF ARTHROPLASTY
- Design, Material, and Seating Load Effects on In Vitro Fretting Corrosion Performance of Modular Head-Neck Tapers
- (2019) Eric S. Ouellette et al. JOURNAL OF ARTHROPLASTY
- Fretting Wear Modeling of Cylindrical Line Contact in Plane-strain Borne by the Finite Element Method
- (2019) Huaidong Yang et al. JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME
- The Influence of Assembly Force on the Material Loss at the Metallic Head-Neck Junction of Hip Implants Subjected to Cyclic Fretting Wear
- (2019) Khosro Fallahnezhad et al. Metals
- The effects of manufacturing tolerances and assembly force on the volumetric wear at the taper junction in modular total hip arthroplasty
- (2019) Thom Bitter et al. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING
- Influence of flexural rigidity on micromotion at the head-stem taper interface of modular hip prostheses
- (2019) Henning Haschke et al. MEDICAL ENGINEERING & PHYSICS
- Taper fretting behavior of PEEK artificial hip joint
- (2019) Handong Xu et al. TRIBOLOGY INTERNATIONAL
- Development of a fretting corrosion model for metallic interfaces using adaptive finite element analysis
- (2018) Khosro Fallahnezhad et al. FINITE ELEMENTS IN ANALYSIS AND DESIGN
- Impaction Force Influences Taper-Trunnion Stability in Total Hip Arthroplasty
- (2018) Jonathan R. Danoff et al. JOURNAL OF ARTHROPLASTY
- Influence of Assembly Force and Distraction on the Femoral Head-Taper Junction
- (2018) Matthew J. Grosso et al. JOURNAL OF ARTHROPLASTY
- Prediction of taper performance using quasi static FE models: The influence of loading, taper clearance and trunnion length
- (2018) Halimat Y. Raji et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
- Finite element wear prediction using adaptive meshing at the modular taper interface of hip implants
- (2018) Thom Bitter et al. Journal of the Mechanical Behavior of Biomedical Materials
- A finite element study on the mechanical response of the head-neck interface of hip implants under realistic forces and moments of daily activities: Part 2
- (2018) Khosro Fallahnezhad et al. Journal of the Mechanical Behavior of Biomedical Materials
- Factors influencing taper failure of modular revision hip stems
- (2018) A. Krull et al. MEDICAL ENGINEERING & PHYSICS
- Modeling and simulation in tribology across scales: An overview
- (2018) A.I. Vakis et al. TRIBOLOGY INTERNATIONAL
- Wear model for describing the time dependence of the material degradation mechanisms of the AISI 316L in a NaCl solution
- (2018) A. Dalmau et al. WEAR
- Head Taper Corrosion Causing Head Bottoming Out and Consecutive Gross Stem Taper Failure in Total Hip Arthroplasty
- (2018) Michael M. Morlock et al. JOURNAL OF ARTHROPLASTY
- Taper-Trunnion Interface Stress Varies Significantly with Head Size and Activity
- (2018) Timothy L. Norman et al. JOURNAL OF ARTHROPLASTY
- A New Asperity-Scale Mechanistic Model of Tribocorrosive Wear: Synergistic Effects of Mechanical Wear and Corrosion
- (2018) Ali Ghanbarzadeh et al. JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME
- An intelligent system for image-based rating of corrosion severity at stem taper of retrieved hip replacement implants
- (2018) Roohollah Milimonfared et al. MEDICAL ENGINEERING & PHYSICS
- The Distribution and Severity of Corrosion Damage at Eight Distinct Zones of Metallic Femoral Stem Implants
- (2018) Roohollah Milimonfared et al. Metals
- Evidence Based Recommendations for Reducing Head-Neck Taper Connection Fretting Corrosion in Hip Replacement Prostheses
- (2017) Christian M. Wight et al. Hip International
- The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty
- (2017) Annika Krull et al. JOURNAL OF ARTHROPLASTY
- Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation
- (2017) Ariyan Ashkanfar et al. JOURNAL OF BIOMECHANICS
- Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements
- (2017) Deborah J. Hall et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
- Reducing fretting-initiated crevice corrosion in hip simulator tests using a zirconia-toughened alumina femoral head
- (2017) Masayuki Kyomoto et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
- A finite element study on the mechanical response of the head-neck interface of hip implants under realistic forces and moments of daily activities: Part 1, level walking
- (2017) Hamidreza Farhoudi et al. Journal of the Mechanical Behavior of Biomedical Materials
- An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: The role of taper angle mismatch
- (2017) Khosro Fallahnezhad et al. Journal of the Mechanical Behavior of Biomedical Materials
- A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: A finite element wear analysis
- (2017) Ariyan Ashkanfar et al. Journal of the Mechanical Behavior of Biomedical Materials
- A new finding on the in-vivo crevice corrosion damage in a CoCrMo hip implant
- (2017) Reza H. Oskouei et al. Materials Science & Engineering C-Materials for Biological Applications
- A combined experimental and finite element approach to analyse the fretting mechanism of the head–stem taper junction in total hip replacement
- (2017) Thom Bitter et al. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE
- Contact size, frequency and cyclic normal force effects on Ti–6Al–4V fretting wear processes: An approach combining friction power and contact oxygenation
- (2017) S. Fouvry et al. TRIBOLOGY INTERNATIONAL
- CORR Insights®: Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?
- (2016) Mariano Fernandez-Fairen CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?
- (2016) Robin Pourzal et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?
- (2016) Christopher Del Balso et al. JOURNAL OF ARTHROPLASTY
- Influence of geometry and materials on the axial and torsional strength of the head–neck taper junction in modular hip replacements: A finite element study
- (2016) Khosro Fallahnezhad et al. Journal of the Mechanical Behavior of Biomedical Materials
- Mechanically assisted crevice corrosion in metallic biomaterials: a review
- (2016) S. A. Mali MATERIALS TECHNOLOGY
- The effect of different assembly loads on taper junction fretting wear in total hip replacements
- (2016) Russell English et al. TRIBOLOGY INTERNATIONAL
- An Analytical Calculation of Frictional and Bending Moments at the Head-Neck Interface of Hip Joint Implants during Different Physiological Activities
- (2016) Hamidreza Farhoudi et al. Materials
- Corrosion at the head-neck interface of current designs of modular femoral components
- (2016) K. Osman et al. Bone & Joint Journal
- Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability
- (2016) A. R. MacLeod et al. Bone & Joint Research
- Optimization algorithms for the solution of the frictionless normal contact between rough surfaces
- (2015) A. Bemporad et al. INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES
- Corrosion and Fretting of a Modular Hip System: A Retrieval Analysis of 60 Rejuvenate Stems
- (2015) Ivan De Martino et al. JOURNAL OF ARTHROPLASTY
- Trunnion–Head Stresses in THA: Are Big Heads Trouble?
- (2015) Carlos J. Lavernia et al. JOURNAL OF ARTHROPLASTY
- Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty
- (2015) Sok Chuen Tan et al. JOURNAL OF ARTHROPLASTY
- A novel analytical approach for determining the frictional moments and torques acting on modular femoral components in total hip replacements
- (2015) H. Farhoudi et al. JOURNAL OF BIOMECHANICS
- Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system
- (2015) Timothy M. Brock et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Influence of stem type on material loss at the metal-on-metal pinnacle taper junction
- (2015) Harry S Hothi et al. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE
- Finite element analysis of the head–neck taper interface of modular hip prostheses
- (2015) R.M.R. Dyrkacz et al. TRIBOLOGY INTERNATIONAL
- The influence of surface hardness on the fretting wear of steel pairs—Its role in debris retention in the contact
- (2015) J.D. Lemm et al. TRIBOLOGY INTERNATIONAL
- A computational approach to fretting wear prediction at the head–stem taper junction of total hip replacements
- (2015) Russell English et al. WEAR
- Head-Neck Taper Corrosion in Hip Arthroplasty
- (2015) S. Hussenbocus et al. Biomed Research International
- Taperosis
- (2015) C. Del Balso et al. Bone & Joint Journal
- Total hip arthroplasty head–neck contact mechanics: A stochastic investigation of key parameters
- (2014) Finn E. Donaldson et al. JOURNAL OF BIOMECHANICS
- Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems
- (2014) S.Y. Jauch et al. MEDICAL ENGINEERING & PHYSICS
- Stability and Trunnion Wear Potential in Large-diameter Metal-on-Metal Total Hips: A Finite Element Analysis
- (2013) Jacob M. Elkins et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Taper Design Affects Failure of Large-head Metal-on-metal Total Hip Replacements
- (2013) Nader A. Nassif et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip Joints
- (2013) Richard M.R. Dyrkacz et al. JOURNAL OF ARTHROPLASTY
- Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings
- (2013) Nicholas Bishop et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Micro–macro wear–fatigue of modular hip implant taper-lock coupling
- (2013) Teng Zhang et al. JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN
- Research on the torsional fretting behavior of the head–neck interface of artificial hip joint
- (2013) Chen Kai et al. MATERIALS & DESIGN
- Why does titanium alloy wear cobalt chrome alloy despite lower bulk hardness: A nanoindentation study?
- (2013) N. Moharrami et al. THIN SOLID FILMS
- A finite element methodology for wear–fatigue analysis for modular hip implants
- (2013) T. Zhang et al. TRIBOLOGY INTERNATIONAL
- Fretting corrosion of CoCrMo and Ti6Al4V interfaces
- (2012) Viswanathan Swaminathan et al. BIOMATERIALS
- The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections
- (2012) M. Baxmann et al. MEDICAL ENGINEERING & PHYSICS
- Mechanical and electrochemical deterioration mechanisms in the tribocorrosion of Al alloys in NaCl and in NaNO3 solutions
- (2011) A.C. Vieira et al. CORROSION SCIENCE
- Accelerating failure rate of the ASR total hip replacement
- (2011) D. J. Langton et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Tribocorrosion modeling of stainless steel in a sliding pair of pin-on-plate type
- (2011) Arkadiusz Stachowiak et al. TRIBOLOGY INTERNATIONAL
Add your recorded webinar
Do you already have a recorded webinar? Grow your audience and get more views by easily listing your recording on Peeref.
Upload NowCreate your own webinar
Interested in hosting your own webinar? Check the schedule and propose your idea to the Peeref Content Team.
Create Now