Reducing fretting-initiated crevice corrosion in hip simulator tests using a zirconia-toughened alumina femoral head
Published 2017 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Reducing fretting-initiated crevice corrosion in hip simulator tests using a zirconia-toughened alumina femoral head
Authors
Keywords
-
Journal
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
Volume -, Issue -, Pages -
Publisher
Wiley
Online
2017-12-20
DOI
10.1002/jbm.b.34062
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion
- (2016) Sevi B. Kocagoz et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Tribocorrosion: Ceramic and Oxidized Zirconium vs Cobalt-Chromium Heads in Total Hip Arthroplasty
- (2016) Sok Chuen Tan et al. JOURNAL OF ARTHROPLASTY
- Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?
- (2016) Christopher Del Balso et al. JOURNAL OF ARTHROPLASTY
- Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings
- (2016) Darren R. Plummer et al. JOURNAL OF ARTHROPLASTY
- Characterization of the fretting corrosion behavior, surface and debris from head-taper interface of two different modular hip prostheses
- (2016) Claudio T. dos Santos et al. Journal of the Mechanical Behavior of Biomedical Materials
- Corrosion at the head-neck interface of current designs of modular femoral components
- (2016) K. Osman et al. Bone & Joint Journal
- Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties
- (2015) Georgios K. Triantafyllopoulos et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Clinically Significant Corrosion at the Head-Neck Taper Interface in Total Hip Arthroplasty: A Systematic Review and Case Series
- (2015) Alberto Carli et al. Hip International
- Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty
- (2015) Sok Chuen Tan et al. JOURNAL OF ARTHROPLASTY
- Head-Neck Taper Corrosion in Hip Arthroplasty
- (2015) S. Hussenbocus et al. Biomed Research International
- Taperosis
- (2015) C. Del Balso et al. Bone & Joint Journal
- What Are the Current Clinical Issues in Wear and Tribocorrosion?
- (2014) Daniel J. Berry et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Directin vivoinflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces
- (2014) Jeremy L. Gilbert et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A
- Galvanically enhanced fretting-crevice corrosion of cemented femoral stems
- (2014) M. Bryant et al. Journal of the Mechanical Behavior of Biomedical Materials
- Does Biolox® Delta ceramic reduce the rate of component fractures in total hip replacement?
- (2014) P. Massin et al. Orthopaedics & Traumatology-Surgery & Research
- Do Ceramic Femoral Heads Reduce Taper Fretting Corrosion in Hip Arthroplasty? A Retrieval Study
- (2013) Steven M. Kurtz et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip Joints
- (2013) Richard M.R. Dyrkacz et al. JOURNAL OF ARTHROPLASTY
- Is Increased Modularity Associated With Increased Fretting and Corrosion Damage in Metal-On-Metal Total Hip Arthroplasty Devices?
- (2013) Genymphas B. Higgs et al. JOURNAL OF ARTHROPLASTY
- Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip Replacements
- (2013) Richard B. Cook et al. JOURNAL OF ARTHROPLASTY
- Potential and frequency effects on fretting corrosion of Ti6Al4V and CoCrMo surfaces
- (2013) Viswanathan Swaminathan et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A
- Radiographic and retrieval wear analyses of the first generation highly cross-linked polyethylene cup against a ceramic femoral head
- (2013) Hiroyuki Oonishi et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
- Advances in zirconia toughened alumina biomaterials for total joint replacement
- (2013) Steven M. Kurtz et al. Journal of the Mechanical Behavior of Biomedical Materials
- Mass Loss and Ion Elution of Biomedical Co–Cr–Mo Alloys during Pin-on-Disk Wear Tests
- (2013) Kyosuke Ueda et al. MATERIALS TRANSACTIONS
- Fretting corrosion of CoCrMo and Ti6Al4V interfaces
- (2012) Viswanathan Swaminathan et al. BIOMATERIALS
- Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty
- (2012) H John Cooper et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation
- (2012) I. P. S. Gill et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Triboelectrochemical techniques and interpretation methods in tribocorrosion: A comparative evaluation
- (2007) S. Mischler TRIBOLOGY INTERNATIONAL
Publish scientific posters with Peeref
Peeref publishes scientific posters from all research disciplines. Our Diamond Open Access policy means free access to content and no publication fees for authors.
Learn MoreAdd your recorded webinar
Do you already have a recorded webinar? Grow your audience and get more views by easily listing your recording on Peeref.
Upload Now