4.6 Article

A Centerline-Based Model Morphing Algorithm for Patient-Specific Finite Element Modeling of the Left Ventricle

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 65, Issue 6, Pages 1391-1398

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2017.2754980

Keywords

Cardiac modelling; echopac (R) ultrasound imaging; model morphing; numerical simulation

Funding

  1. Center for Cardiological Innovation - Research Council of Norway
  2. European Research Council

Ask authors/readers for more resources

Goal: Hexahedral automatic model generation is a recurrent problem in computer vision and computational biomechanics. It may even become a challenging problem when one wants to develop a patient-specific finite element (FE) model of the left ventricle (LV), particularly when only low resolution images are available. In the present study, a fast and efficient algorithm is presented and tested to address such a situation. Methods: A template FE hexahedral model was created for an LV geometry using a general electric ultrasound (US) system. A system of centerline was considered for this LV mesh. Then, the nodes located over the endocardial and epicardial surfaces are, respectively, projected from this centerline onto the actual endocardial and epicardial surfaces reconstructed from a patient's US data. Finally, the position of the internal nodes is derived by finding the deformations with minimal elastic energy. This approach was applied to eight patients suffering from congestive heart disease. An FE analysis was performed to derive the stress induced in the LV tissue by diastolic blood pressure on each of them. Results: Our model morphing algorithm was applied successfully and the obtained meshes showed only marginal mismatches when compared to the corresponding US geometries. The diastolic FE analyses were successfully performed in seven patients to derive the distribution of principal stresses. Conclusion: The original model morphing algorithm is fast and robust with low computational cost. Significance: This low-cost model morphing algorithm may be highly beneficial for future patient-specific reduced-order modeling of the LV with potential application to other crucial organs.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available