Impact Force, Polar Gap and Modal Parameters Predict Acetabular Cup Fixation: A Study on a Composite Bone
Published 2018 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Impact Force, Polar Gap and Modal Parameters Predict Acetabular Cup Fixation: A Study on a Composite Bone
Authors
Keywords
Pelvis, Experimental modal analysis, Gaussian process, Functional principal component analysis, Frequency response function, Surrogate model
Journal
ANNALS OF BIOMEDICAL ENGINEERING
Volume 46, Issue 4, Pages 590-604
Publisher
Springer Nature
Online
2018-01-17
DOI
10.1007/s10439-018-1980-3
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Stability of small pegs for cementless implant fixation
- (2017) Diogo M. Geraldes et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Determination of the acetabular cup implant stability using an acoustic method based on the impact between the hammer and the ancillary
- (2017) Giuseppe Rosi et al. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA
- Non-invasive vibrometry-based diagnostic detection of acetabular cup loosening in total hip replacement (THR)
- (2017) Abdullah A. Alshuhri et al. MEDICAL ENGINEERING & PHYSICS
- Development of Implant Stability Quotient values of implants placed with simultaneous sinus floor elevation - results of a prospective study with 109 implants
- (2016) Ulrike Kuchler et al. CLINICAL ORAL IMPLANTS RESEARCH
- Ex vivo estimation of cementless acetabular cup stability using an impact hammer
- (2016) Adrien Michel et al. MEDICAL ENGINEERING & PHYSICS
- Automated modal identification and tracking: Application to an iron arch bridge
- (2016) Alessandro Cabboi et al. Structural Control & Health Monitoring
- Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study
- (2016) Adrien Michel et al. PLoS One
- Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements
- (2015) Abdullah A. Alshuhri et al. MEDICAL ENGINEERING & PHYSICS
- Evaluation of acetabular cup initial fixation by using resonance frequency principle
- (2015) Petr Henys et al. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE
- Factors influencing initial cup stability in total hip arthroplasty
- (2014) Farid Amirouche et al. CLINICAL BIOMECHANICS
- Initial Stability of Press-Fit Acetabular Components Under Rotational Forces
- (2013) Keith A. Fehring et al. JOURNAL OF ARTHROPLASTY
- Population-Based Rates of Revision of Primary Total Hip Arthroplasty: A Systematic Review
- (2010) Kelly L. Corbett et al. PLoS One
- Mechanical Stability of Novel Highly Porous Metal Acetabular Components in Revision Total Hip Arthroplasty
- (2009) R. Michael Meneghini et al. JOURNAL OF ARTHROPLASTY
- In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses
- (2009) Leonard C Pastrav et al. Journal of Orthopaedic Surgery and Research
- A Prospective Outcomes Analysis of Femoral Component Fixation in Revision Total Hip Arthroplasty
- (2008) Richard Iorio et al. JOURNAL OF ARTHROPLASTY
- Experimental investigations of the insertion and deformation behavior of press-fit and threaded acetabular cups for total hip replacement
- (2008) Andreas Fritsche et al. JOURNAL OF ORTHOPAEDIC SCIENCE
- Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications
- (2008) Lars Sennerby et al. PERIODONTOLOGY 2000
Discover Peeref hubs
Discuss science. Find collaborators. Network.
Join a conversationCreate your own webinar
Interested in hosting your own webinar? Check the schedule and propose your idea to the Peeref Content Team.
Create Now