Fluorescence spectroscopy was used as a characterization method to examine organic fouling of single ultrafiltration (UF) fibres at bench-scale. Low doses of coagulant were applied to modify organic properties, without significant formation of precipitates. This approach compliments previous studies investigating coagulation as a pre-treatment method for UF fouling control, which have principally focused on reduction of foulant concentrations. Using a continuous system, short time-scale fluorescence results demonstrated significant adsorption of humic components to virgin membrane fibres. Following an initial adsorption phase, protein-like material was the only organic component to be significantly removed by UF. Low doses of coagulant (< 1 mg/L as alum; < 0.043 mg/L as Al3+) were observed to significantly reduce irreversible fouling rates for two different surface waters. Paralleling reduced irreversible fouling, surface tryptophan fluorescence resulting from material adsorbed to the fouled membrane increased, as measured using a fibre optic probe. Analysis of peak shifts in the protein-like component revealed a red-shift at low coagulant dose, possibly indicative of greater exposure of tryptophan residues resulting from conformational changes in the protein structure. It is hypothesized that low coagulant doses modified membrane-foulant interactions, resulting in increased adsorption of protein-like matter to the surface. Subsequent interactions of bulk foulants with the adsorbed organic monolayer discouraged further adsorption and reduced irreversible fouling potential. (C) 2017 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available