4.6 Article

Selectivity Enhancement for Uric Acid Detection via In Situ Preparation of Blue Emissive Carbon Dots Entrapped in Chromium Metal-Organic Frameworks

Journal

ACS OMEGA
Volume 7, Issue 19, Pages 16576-16583

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsomega.2c00790

Keywords

-

Funding

  1. University of Sulaimani
  2. College of Science and Department of Chemistry of Sulaimani University

Ask authors/readers for more resources

In this study, the in situ formation of blue emissive carbon dots (bCDs) and their encapsulation into chromium-based metal-organic frameworks (CrMOFs) are described for the first time. The resulting bCDs@Cr-MOFs nanocomposite exhibits strong blue emission and high selectivity towards uric acid. The method demonstrates high stability and reliability.
In the present work, for the first time, the in situ formation of blue emissive carbon dots (bCDs) and encapsulation into the pores of chromium-based metal-organic frameworks (CrMOFs) are described. The luminescent bCDs via in situ process are formed and entrapped inside the pores of Cr-MOFs to form a nanocomposite of bCDs@Cr-MOFs. The bCDs@Cr-MOFs showed a strong broad blue emission at 420 nm (excited at 310 nm), which corresponds to both, the ligand (2-aminoterephthalic acid) in the Cr-MOF and the entrapped bCDs. This is assigned for the entrapping of bCDs in the pores of the MOFs. Additionally, transmission electron microscopy (TEM) images showed two types of particles, 150 rod-like shapes for Cr-MOF and 5-10 nm spherical shapes assigned for the presence of bCDs. The bCDs alone (without Cr-MOF) showed no selectivity, and their emission was quenched by different biomolecules and ions, such as ascorbic acid, uric acid, Fe3+, Cu2+, and Hg2+. The selectivity of bCDs toward uric acid was increased dramatically when they were encapsulated in the Cr-MOF. The linear range for uric acid was 20-50 mu M, and the LOD was measured as 1.3 mu M. Spike recoveries for the detection of uric acid in serum samples were between 94 and 108%. The relative standard deviation (RSD, n = 3) at each concentration value was less than 2%. The results showed high ruggedness and robustness of the assay due to its high shelf-life stability of probe (four weeks), water stability, and long working pH range. Validation experiments showed that the established MOF-based sensing system is appropriate for uric acid detection in real samples

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available