4.7 Article

Efficiency enhancement of the spectrophotometric estimation of cobalt in waters and pharmaceutical preparations using dispersive liquid? liquid microextraction and microcells with long optical paths

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.saa.2021.119552

Keywords

Cobalt; Determination; Microcell; Spectrophotometry; Characterization

Categories

Funding

  1. Taif University ,Taif, Saudi Arabia [TURSP-2020/90]
  2. Taif University

Ask authors/readers for more resources

In this study, a new analytical method for cobalt determination was developed by using DLLME, long optical path microcells, and a selective chromogenic reagent. The method successfully determined the concentration of cobalt in the linear range through microextraction and measurement in a microcell with a 50mm optical path length.
In this paper, dispersive liquid?liquid microextraction (DLLME), long optical path microcells, and a selective chromogenic reagent were employed to improve the analytical efficiency of cobalt determination by spectrophotometry. The methodology proposed in the present study is based upon the microextraction of a cobalt(II) complex with 1-[4-[(2-hydroxynaphthalen-1-yl)methylideneamino] phenyl]ethanone (HNE) by DLLME and measurement of the absorbance of the sedimented phase using a microcell with an optical path length of 50 mm (Microcell?50). DLLME was performed using a binary mixture containing 900 ?L of methanol as a dispersing solvent and 400 ?L of CHCl3 (extraction solvent) at pH 6?8 adjusted by a mixture of HCl and NaOH. The electronic spectrum of the dark brown complex recorded in the sedimented phase using Microcell?50 shows a well-defined peak at Amax 324 ? 3 nm with a molar absorptivity of 1.08 x 106 M-1 cm-1. Cobalt was monitored at a detection limit (LOD) of 0.08 ?g L?1 and in the linear concentration range of 0.45?10 ?g L?1, while the limit of quantitation (LOQ), relative standard deviation (RSD), and the enhancement factor (EF) were 0.264, 1.6 ?gL?1, and 223, respectively. Our method was evaluated by determining cobalt in certified reference materials and experimental samples, and the results were compared with ICP?MS measurements. Moreover, the chemical structure of the [Co (C38H28O2N)2] complex was suggested through using different characterization techniques such as Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), thermal analysis, and powder X-ray diffraction. (c) 2021 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available