BVS stent optimisation based on a parametric model with a multistage validation process
Published 2020 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
BVS stent optimisation based on a parametric model with a multistage validation process
Authors
Keywords
BVS, Bioresorbable material, Optimisation, FEA, In vivo validation
Journal
MATERIALS & DESIGN
Volume 198, Issue -, Pages 109363
Publisher
Elsevier BV
Online
2020-11-29
DOI
10.1016/j.matdes.2020.109363
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Experimental and numerical flow analysis through arteries with stent using particle image velocimetry and computational fluid dynamics method
- (2020) Michał Tomaszewski et al. Biocybernetics and Biomedical Engineering
- On the importance of modeling balloon folding, pleating, and stent crimping: a FE study comparing experimental inflation tests
- (2019) Markus A. Geith et al. International Journal for Numerical Methods in Biomedical Engineering
- Structural and Hemodynamic Analyses of Different Stent Structures in Curved and Stenotic Coronary Artery
- (2019) Lingling Wei et al. Frontiers in Bioengineering and Biotechnology
- Numerical analysis of crimping and inflation process of balloon-expandable coronary stent using implicit solution
- (2017) Jakub Bukala et al. International Journal for Numerical Methods in Biomedical Engineering
- Bioresorbable stents: Current and upcoming bioresorbable technologies
- (2017) Hui Ying Ang et al. INTERNATIONAL JOURNAL OF CARDIOLOGY
- Arterial Remodeling After Bioresorbable Scaffolds and Metallic Stents
- (2017) Patrick W. Serruys et al. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
- Computational and experimental investigation into mechanical performances of Poly-L-Lactide Acid (PLLA) coronary stents
- (2017) Qian Wang et al. Journal of the Mechanical Behavior of Biomedical Materials
- Numerical analysis of stent expansion process in coronary artery stenosis with the use of non-compliant balloon
- (2016) Jakub Bukala et al. Biocybernetics and Biomedical Engineering
- Is bioresorbable vascular scaffold acute recoil affected by baseline renal function and scaffold selection?
- (2016) Haci Murat Gunes et al. INTERNATIONAL JOURNAL OF CARDIOLOGY
- Incidence, predictive factors, and clinical impact of stent recoil in stent fracture lesion after drug-eluting stent implantation
- (2016) Masanobu Ohya et al. INTERNATIONAL JOURNAL OF CARDIOLOGY
- Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses
- (2016) Claudio Chiastra et al. JOURNAL OF BIOMECHANICS
- Numerical simulation on the effects of drug eluting stents at different Reynolds numbers on hemodynamic and drug concentration distribution
- (2015) Yu Chen et al. Biomedical Engineering Online
- Very late bioresorbable vascular scaffold thrombosis due to late device recoil
- (2015) Bernardo Cortese et al. INTERNATIONAL JOURNAL OF CARDIOLOGY
- A finite element strategy to investigate the free expansion behaviour of a biodegradable polymeric stent
- (2015) Nic Debusschere et al. JOURNAL OF BIOMECHANICS
- Computational analysis of the radial mechanical performance of PLLA coronary artery stents
- (2015) R.G. Pauck et al. MEDICAL ENGINEERING & PHYSICS
- Parametrical optimization of stent design; a numerical-based approach
- (2014) Amirmostafa Amirjani et al. COMPUTATIONAL MATERIALS SCIENCE
- Impact of coronary stent designs on acute stent recoil
- (2014) Tomoyuki Ota et al. Journal of Cardiology
- Nitinol stent design – understanding axial buckling
- (2014) D.J. McGrath et al. Journal of the Mechanical Behavior of Biomedical Materials
- Optimizing the design of a bioabsorbable metal stent using computer simulation methods
- (2013) James A. Grogan et al. BIOMATERIALS
- Acute Stent Recoil From Aggressive Post-Dilation of a Second-Generation Drug-Eluting Stent
- (2013) Kensuke Takagi et al. JACC-Cardiovascular Interventions
- Patient-specific simulations of stenting procedures in coronary bifurcations: Two clinical cases
- (2013) Stefano Morlacchi et al. MEDICAL ENGINEERING & PHYSICS
- Immediate stent recoil in an anastomotic vein graft lesion treated by cutting balloon angioplasty
- (2013) Nuri Ilker Akkus et al. Revista Portuguesa de Cardiologia
- Self-expanding aortic valve stent—Material optimization
- (2012) Gideon Praveen Kumar et al. COMPUTERS IN BIOLOGY AND MEDICINE
- Reducing In-Stent Restenosis Through Novel Stent Flow Field Augmentation
- (2012) Eoin A. Murphy et al. Cardiovascular Engineering and Technology
- Multiobjective design optimisation of coronary stents
- (2011) Sanjay Pant et al. BIOMATERIALS
- Computational comparison of the bending behavior of aortic stent-grafts
- (2011) Nicolas Demanget et al. Journal of the Mechanical Behavior of Biomedical Materials
- Challenges related to development of bioabsorbable vascular stents
- (2011) Joseph Berglund et al. EuroIntervention
- Finite Element Shape Optimization for Biodegradable Magnesium Alloy Stents
- (2010) W. Wu et al. ANNALS OF BIOMEDICAL ENGINEERING
- Intracoronary Optical Coherence Tomography and Histology at 1 Month and 2, 3, and 4 Years After Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffolds in a Porcine Coronary Artery Model
- (2010) Yoshinobu Onuma et al. CIRCULATION
- Coronary Stents
- (2010) Scot Garg et al. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
- Shape optimization of coronary artery stent based on a parametric model
- (2009) Ning Li et al. FINITE ELEMENTS IN ANALYSIS AND DESIGN
- Virtual optimization of self-expandable braided wire stents
- (2009) Matthieu De Beule et al. MEDICAL ENGINEERING & PHYSICS
- On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method
- (2008) Francesca Gervaso et al. JOURNAL OF BIOMECHANICS
- Late Stent Recoil of the Bioabsorbable Everolimus-Eluting Coronary Stent and its Relationship With Plaque Morphology
- (2008) Shuzou Tanimoto et al. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
- Realistic finite element-based stent design: The impact of balloon folding
- (2007) Matthieu De Beule et al. JOURNAL OF BIOMECHANICS
Find the ideal target journal for your manuscript
Explore over 38,000 international journals covering a vast array of academic fields.
SearchBecome a Peeref-certified reviewer
The Peeref Institute provides free reviewer training that teaches the core competencies of the academic peer review process.
Get Started