4.5 Article

In-Vitro Assessment of the Effects of Transcatheter Aortic Valve Leaflet Design on Neo-Sinus Geometry and Flow

Journal

ANNALS OF BIOMEDICAL ENGINEERING
Volume 49, Issue 3, Pages 1046-1057

Publisher

SPRINGER
DOI: 10.1007/s10439-020-02664-0

Keywords

TAVR; Leaflet thrombosis; Neo-sinus; Leaflet length; Leaflet insertion height; Flow stasis; Leaflet kinematics; Particle image velocimetry

Funding

  1. Mary and James Wesley Fellowship Endowment
  2. American Association of University Women

Ask authors/readers for more resources

Shorter transcatheter aortic valve leaflet length is associated with reduced particle residence time and flow stagnation in the neo-sinus, potentially lowering the risk of leaflet thrombosis.
Transcatheter aortic valve (TAV) leaflet thrombosis is a clinical risk with potentially fatal consequences. Studies have identified neo-sinus flow stasis as a cause of leaflet thrombosis. Flow stasis is influenced by the TAV leaflets, which affect the local fluid dynamics in the aortic sinus and neo-sinus. This study evaluated the effects of TAV leaflet features on the neo-sinus flow as a measure of leaflet thrombosis risk. Five TAVs of varied leaflet length and insertion height were tested in a simulator. Hydrodynamics and leaflet kinematics through en-phase imaging were quantified. Velocity fields were assessed using high-speed particle image velocimetry. Regions of flow stasis and particle residence times (PRTs) were quantified. TAVs with shorter leaflet length exhibited larger orifice areas and lower transvalvular pressure gradients. Shorter leaflet length and increased leaflet insertion TAVs additionally exhibited lower neo-sinus PRTs (0.44 +/- 0.21 vs 2.83 +/- 0.48 cycles, p < 0.05) and higher neo-sinus peak velocities (0.15 +/- 0.009 vs 0.07 +/- 0.005 m/s, p < 0.05) than TAVs with longer leaflet length and lower leaflet insertion. The average neo-sinus volume positively correlated with PRT(r = 0.810, p < 0.001), and extent of flow stasis (r = 0.682, p < 0.05). These results suggest that a small neo-sinus volume may reduce flow stagnation and particle residence, potentially reducing the risk of leaflet thrombosis. We propose that leaflet design features might be proactively controlled in the design of future transcatheter aortic valves.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available