4.7 Article

Combined effects of Carbon Fiber Reinforced Polymer flexural reinforcements and post installed shear dowels on the performance of flat slabs

Journal

COMPOSITE STRUCTURES
Volume 236, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.compstruct.2019.111848

Keywords

CFRP dowels; Externally bonded CFRP; Punching shear; Slab-column interface

Funding

  1. Senate Research Council (SRC), University of Moratuwa, Sri Lanka [SRC/LT/2017/23]

Ask authors/readers for more resources

The sudden punching shear failure of flat slabs is a critical issue. The combined effects of externally strengthened Carbon Fiber Reinforced Polymer (CFRP) flexural reinforcements and post-installed CFRP shear reinforcements which explain the real behavior in the strengthening phase of a shear deficient slab, on the punching shear performance are not fully explained. In this study, the flat slab panels of 1200 mm x 1200 mm x 100 mm were retrofitted with seven alternative bonding arrangements of CFRP to investigate the combined effects of shear dowels and flexural reinforcements. A transient load was applied using a stub column, size 100 mm x 100 mm located at the center of the slab. The non-strengthened specimens failed in punching shear. The strengthened specimens showed a maximum punching shear capacity enhancement of 120%. A numerical model was also developed to identify the load transfer behavior of post-installed CFRP shear dowels. Further, the effects from the end anchorage of external CFRP and the refilling material at drilled locations to install CFRP shear strengthening scheme were also determined.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available