The sudden punching shear failure of flat slabs is a critical issue. The combined effects of externally strengthened Carbon Fiber Reinforced Polymer (CFRP) flexural reinforcements and post-installed CFRP shear reinforcements which explain the real behavior in the strengthening phase of a shear deficient slab, on the punching shear performance are not fully explained. In this study, the flat slab panels of 1200 mm x 1200 mm x 100 mm were retrofitted with seven alternative bonding arrangements of CFRP to investigate the combined effects of shear dowels and flexural reinforcements. A transient load was applied using a stub column, size 100 mm x 100 mm located at the center of the slab. The non-strengthened specimens failed in punching shear. The strengthened specimens showed a maximum punching shear capacity enhancement of 120%. A numerical model was also developed to identify the load transfer behavior of post-installed CFRP shear dowels. Further, the effects from the end anchorage of external CFRP and the refilling material at drilled locations to install CFRP shear strengthening scheme were also determined.