Development and Calibration of an Organic-Diffusive Gradients in Thin Films Aquatic Passive Sampler for a Diverse Suite of Polar Organic Contaminants

Journal

ANALYTICAL CHEMISTRY
Volume 88, Issue 21, Pages 10583-10591

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.6b02749

Keywords

-

Funding

  1. Natural Sciences and Engineering Research Council of Canada
  2. CREATE-H2O program
  3. Vanier Scholarship
  4. Canada Research Chairs Program

Ask authors/readers for more resources

A unique configuration of the diffusive gradients in thin films sampler for polar organics (o-DGT) without a poly(ether sulfone) membrane was developed, calibrated, and field-evaluated. Diffusion coefficients (D) through agarose diffusive gels ranged from (1.02 to 4.74) x 10(-6) cm(2)/s for 34 pharmaceuticals and pesticides at 5, 13, and 23 degrees C. Analyte-specific diffusiontemperature plots produced linear (r(2) > 0.85) empirical relationships whereby D could be estimated at any environmentally relevant temperature (i.e., matched to in situ water conditions). Linear uptake for all analytes was observed in a static renewal calibration experiment over 25 days except for three macrolide antibiotics, which reached saturation at 300 ng (15 d). Experimental sampling rates ranged from 8.8 to 16.1 mL/d and were successfully estimated with measured and modeled D within 19% and 30% average relative error, respectively. Under slow flowing (2.4 cm/s) and static conditions, the in situ diffusive boundary layer (DBL) thickness ranged from 0.023 to 0.075 cm, resulting in a maximum contribution to mass transfer of <45%. Estimated water concentrations by o-DGT at a wastewater treatment plant agreed well with grab samples and appeared to be less influenced by the boundary layer compared to that of polar organic chemical integrative samplers (POCIS) deployed simultaneously. The o-DGT sampler is a promising monitoring tool that is largely insensitive to the DBL under typical flow conditions, facilitating the application of measured/modeled diffusion-based sampling rates. This significantly reduces the need for sampler calibration, making o-DGT more widely applicable, reliable, and cost-effective compared to current polar passive samplers.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available