4.7 Article

Determination of phenol by flow-injection with chemiluminescence detection based on the hemin-catalysed luminol-hydrogen peroxide reaction

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.saa.2011.10.008

Keywords

Flow injection; Chemiluminescence; Phenol; Luminol; Hydrogen peroxide; Hemin

Categories

Funding

  1. China National 863 Project [2006BAE01A08-01]
  2. University of Jinan [XBS0908]

Ask authors/readers for more resources

This study established a novel flow injection (FI) methodology for the determination of phenol in aqueous samples based on luminol chemiluminescence (CL) detection. The method was based on the inhibition that phenol caused on the hemin-catalysed chemiluminescence reaction between luminol and hydrogen peroxide in alkaline solution. Optimum conditions and possible mechanisms have been investigated. The linear range was 2.0 x 10(-9) to 4.0 x 10(-7) g mL(-1) for phenol. The proposed method is sensitive with a detection limit of 4.0 x 10(-19) g ml(-1). The relative standard deviation for 11 measurements was 2.3% for 1.0 x 10(-7)g mL(-1) phenol. The method was applied for the determination of phenol in waste water samples. The results obtained compared well with those by an official method. (C) 2011 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available