4.7 Article

The absorption spectrum of D2: Ultrasensitive cavity ring down spectroscopy of the (2-0) band near 1.7 μm and accurate ab initio line list up to 24 000 cm-1

Journal

JOURNAL OF CHEMICAL PHYSICS
Volume 136, Issue 18, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.4707708

Keywords

-

Funding

  1. Polish Ministry of Science and Higher Education [N N204 015338]

Ask authors/readers for more resources

Eleven very weak electric quadrupole transitions Q(2), Q(1), S(0)-S(8) of the first overtone band of D-2 have been measured by very high sensitivity CW-cavity ring down spectroscopy (CRDS) between 5850 and 6720 cm(-1). The noise equivalent absorption of the recordings is on the order of alpha(min) approximate to 3 x 10(-11) cm(-1). By averaging a high number of spectra, the noise level was lowered to alpha(min) approximate to 4 x 10(-12) cm(-1) in order to detect the S(8) transition which is among the weakest transitions ever detected in laboratory experiments (line intensity on the order of 1.8 x 10(-31) cm/molecule at 296 K). A Galatry profile was used to reproduce the measured line shape and derive the line strengths. The pressure shift and position at zero pressure limit were determined from recordings with pressures ranging between 10 and 750 Torr. A highly accurate theoretical line list was constructed for pure D-2 at 296 K. The intensity threshold was fixed to a value of 1 x 10(-34) cm/molecule at 296 K. The obtained line list is provided as supplementary material. It extends up to 24 000 cm-1 and includes 201 transitions belonging to ten nu-0 cold bands (nu = 0-9) and three nu-1 hot bands (nu = 1-3). The energy levels include the relativistic and quantum electrodynamic corrections as well as the effects of the finite nuclear mass. The quadrupole transition moments are calculated using highly accurate adiabatic wave functions. The CRDS line positions and intensities of the first overtone band are compared to the corresponding calculated values and to previous measurements of the S(0)-S(3) lines. The agreement between the CRDS and theoretical results is found within the claimed experimental uncertainties (on the order of 1 x 10(-3) cm(-1) and 2% for the positions and intensities, respectively) while the previous S(0)-S(3) measurements showed important deviations for the line intensities. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4707708]

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available