Local and systemic toxicity of nanoscale debris particles in total hip arthroplasty
Published 2012 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Local and systemic toxicity of nanoscale debris particles in total hip arthroplasty
Authors
Keywords
-
Journal
JOURNAL OF APPLIED TOXICOLOGY
Volume 32, Issue 4, Pages 255-269
Publisher
Wiley
Online
2012-02-11
DOI
10.1002/jat.2729
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Metal-on-metal Bearing Surfaces
- (2016) Joshua J. Jacobs et al. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS
- Cancer risk is not increased after conventional hip arthroplasty
- (2010) Tuomo Visuri et al. Acta Orthopaedica
- Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty
- (2010) Anton H Hosman et al. Acta Orthopaedica
- A retrospective comparative study of mortality and causes of death among patients with metal-on-metal and metal-on-polyethylene total hip prostheses in primary osteoarthritis after a long-term follow-up
- (2010) Tuomo Visuri et al. BMC MUSCULOSKELETAL DISORDERS
- Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement
- (2010) D. J. Langton et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- TiO2 nanoparticles translocation and potential toxicological effect in rats after intraarticular injection
- (2009) Jiang-Xue Wang et al. BIOMATERIALS
- NanoGenotoxicology: The DNA damaging potential of engineered nanomaterials
- (2009) Neenu Singh et al. BIOMATERIALS
- Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophagesin vitro
- (2009) Young-Min Kwon et al. Biomedical Materials
- Alterations of histone modifications by cobalt compounds
- (2009) Qin Li et al. CARCINOGENESIS
- Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings
- (2009) J. Daniel et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia
- (2009) A. J. Hart et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- The painful metal-on-metal hip resurfacing
- (2009) A. J. Hart et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Blood metal ion concentrations after hip resurfacing arthroplasty
- (2009) D. J. Langton et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Nephrotoxicity effects of the wood preservative chromium copper arsenate on mice: Histopathological and quantitative approaches
- (2009) Rita Cerejeira Matos et al. JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY
- Nongenomic Signaling Pathways of Estrogen Toxicity
- (2009) Cheryl S. Watson et al. TOXICOLOGICAL SCIENCES
- Toxicity of antimony trioxide nanoparticles on human hematopoietic progenitor cells and comparison to cell lines
- (2009) Lisa Bregoli et al. TOXICOLOGY
- Metal-on-metal hip resurfacing arthroplasty: A review of periprosthetic biological reactions
- (2008) Guillaume Mabilleau et al. Acta Orthopaedica
- Does Ion Release Differ Between Hip Resurfacing and Metal-on-metal THA?
- (2008) Antonio Moroni et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Distribution of Chromium and Cobalt Ions in Various Blood Fractions After Resurfacing Hip Arthroplasty
- (2008) Leonard R. Walter et al. JOURNAL OF ARTHROPLASTY
- Metal-on-metal bearings in total hip arthroplasties: Influence of cobalt and chromium ions on bacterial growth and biofilm formation
- (2008) Anton H. Hosman et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A
- Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing
- (2008) K De Smet et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Metal Ion Levels in the Blood of Patients After Hip Resurfacing: A Comparison Between Twenty-eight and Thirty-six-Millimeter-Head Metal-on-Metal Prostheses
- (2008) John Antoniou et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Pseudotumours associated with metal-on-metal hip resurfacings
- (2008) H. Pandit et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: A novel mechanism for implant debris reactivity
- (2008) Marco S. Caicedo et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- The effect of particle design on cellular internalization pathways
- (2008) S. E. A. Gratton et al. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA
- Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty
- (2008) Nadim Hallab et al. Journal of Orthopaedic Surgery and Research
- Analysis of metal ion-induced DNA damage, apoptosis, and necrosis in human (Jurkat) T-cells demonstrates Ni2+and V3+are more toxic than other metals: Al3+, Be2+, Co2+, Cr3+, Cu2+, Fe3+, Mo5+, Nb5+, Zr2+
- (2007) Marco Caicedo et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A
- Variations in astrocyte and fibroblast response due to biomaterial particulatesin vitro
- (2007) Roche C. de Guzman et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A
Publish scientific posters with Peeref
Peeref publishes scientific posters from all research disciplines. Our Diamond Open Access policy means free access to content and no publication fees for authors.
Learn MoreAsk a Question. Answer a Question.
Quickly pose questions to the entire community. Debate answers and get clarity on the most important issues facing researchers.
Get Started