Patient-specific positioning guides for total knee arthroplasty: no significant difference between final component alignment and pre-operative digital plan except for tibial rotation
Published 2015 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Patient-specific positioning guides for total knee arthroplasty: no significant difference between final component alignment and pre-operative digital plan except for tibial rotation
Authors
Keywords
-
Journal
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
Volume 25, Issue 9, Pages 2809-2817
Publisher
Springer Nature
Online
2015-06-11
DOI
10.1007/s00167-015-3661-1
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Assessing the accuracy of patient-specific guides for total knee arthroplasty
- (2014) Jong-Keun Seon et al. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
- Patient-specific Guides Do Not Improve Accuracy in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial
- (2013) Jan Victor et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Is TKA Using Patient-specific Instruments Comparable to Conventional TKA? A Randomized Controlled Study of One System
- (2013) Yoon Whan Roh et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- A comparison of conventional and patient-specific instruments in total knee arthroplasty
- (2013) Kiriakos Daniilidis et al. INTERNATIONAL ORTHOPAEDICS
- In-Vivo Alignment Comparing Patient Specific Instrumentation with both Conventional and Computer Assisted Surgery (CAS) Instrumentation in Total Knee Arthroplasty
- (2013) William Barrett et al. JOURNAL OF ARTHROPLASTY
- Can technology improve alignment during knee arthroplasty
- (2013) Emmanuel Thienpont et al. KNEE
- Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial
- (2013) B. Boonen et al. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
- Patient-specific instrumentation improves tibial component rotation in TKA
- (2013) Alcindo Silva et al. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
- Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation
- (2013) Sébastien Parratte et al. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
- Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation
- (2013) Corey Scholes et al. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
- A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement
- (2013) K. Chareancholvanich et al. Bone & Joint Journal
- Preliminary experience with the patient-specific templating total knee arthroplasty
- (2012) Bert Boonen et al. Acta Orthopaedica
- Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty
- (2012) Sébastien Lustig et al. JOURNAL OF ARTHROPLASTY
- Evaluation of the accuracy of a patient-specific instrumentation by navigation
- (2012) Fabio Conteduca et al. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
- Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008
- (2011) Øystein Gøthesen et al. Acta Orthopaedica
- The effect of pelvic movement on the accuracy of hip centre location acquired using an imageless navigation system
- (2011) Sebastien Lustig et al. INTERNATIONAL ORTHOPAEDICS
- The position and orientation of total knee replacement components
- (2011) M. T. Hirschmann et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?
- (2011) Tao Cheng et al. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
- Joint Replacement Access in 2016
- (2010) Thomas K. Fehring et al. JOURNAL OF ARTHROPLASTY
- Alignment Deviation Between Bone Resection and Final Implant Positioning in Computer-Navigated Total Knee Arthroplasty
- (2008) Fabio Catani et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
Become a Peeref-certified reviewer
The Peeref Institute provides free reviewer training that teaches the core competencies of the academic peer review process.
Get StartedAsk a Question. Answer a Question.
Quickly pose questions to the entire community. Debate answers and get clarity on the most important issues facing researchers.
Get Started