4.5 Article Proceedings Paper

Results of transcaval embolization for sac expansion from type II endoleaks after endovascular aneurysm repair

Journal

JOURNAL OF VASCULAR SURGERY
Volume 61, Issue 5, Pages 1129-1136

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.jvs.2014.12.002

Keywords

-

Ask authors/readers for more resources

Objective: Management of type II endoleaks after endovascular aneurysm repair can be problematic. This study reports our experience with a relatively novel strategy to treat this complication, transcaval coil embolization (TCCE) of the aneurysm sac. Methods: We reviewed 29 consecutive patients undergoing TCCE from 2010 to 2013. Demographics, operative details, and outcomes were assessed. Results: Since 2006, 29 TCCEs have been performed at our institution in 26 patients for sac expansion from type II endoleaks. Patients were male (83%) and former or current smokers (88%), with an average age of 78 +/- 7.1 years. TCCE was performed a mean of 4.2 +/- 4 years after initial endovascular aneurysm repair. Endoleaks resulted in a mean sac growth of 1.2 +/- 1 cm in diameter and 37% +/- 32% by volume. Forty-six percent had prior procedures (5 translumbar, 3 transarterial, 3 transcaval, 1 aortic cuff, and 1 iliac limb extension). Two patients had no flow identified in the aneurysm sac after puncture was successful, and one was found to have a hygroma rather than arterial flow. An additional two patients had ultimate embolization from sac access between the endograft iliac limb and arterial wall after transcaval puncture failed, for a 90% procedural success (83% for transcaval technical success). Mean fluoroscopy time was 27 +/- 13 minutes with 29 +/- 21 mL of contrast material used and a median of 10 coils per case. Additional adjuncts included thrombin injection (17%), intravascular ultrasound (14%), sac pressure measurements (28%), and on-table integrated computed tomography (17%). Median length of stay was 1 day (range, 0-5 days). There were no procedural adverse events. Reintervention was required in five cases (three repeated TCCEs, two graft relinings). One-year freedom from reintervention was 95%. At a mean 16.5 months of follow-up, 70% experienced no further endoleak and had stable or decreasing sac diameters. There have been no ruptures during follow-up. Conclusions: In this series, TCCE for treatment of aneurysm enlargement due to type II endoleaks was safe and relatively effective despite prior failed interventions in nearly half of the cases. TCCE is a useful alternative in cases in which the anatomy makes other approaches difficult or impossible.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available