4.7 Article

Decontamination of Salmonella enterica Typhimurium on green onions using a new formula of sanitizer washing and pulsed UV light (PL)

Journal

FOOD RESEARCH INTERNATIONAL
Volume 62, Issue -, Pages 280-285

Publisher

ELSEVIER
DOI: 10.1016/j.foodres.2014.03.005

Keywords

Salmonella; Green onions; New formula sanitizer; Pulsed light (PL)

Funding

  1. Agriculture and Food Research Initiative Competitive Grants Program of the USDA National Institute of Food and Agriculture, NIFA [2011-68003-30005]

Ask authors/readers for more resources

Pathogenic bacteria such as Salmonella and Shigella flexneri have been linked to green onion contamination. This study was conducted to evaluate decontamination of Salmonella Typhimurium using a new formula of sanitizer washing (0.4 mg/mL thymol and five new formula sanitizers including 300 ppm H2O2 + 4% SDS, 2 mg/mL citric acid + 4% SDS, 0.2 mg/mL thymol + 4% SDS, 0.2 mg/mL thymol + 2 mg/mL citric acid and 0.2 mg/mL thymol + 2 mg/mL acetic acid), pulsed UV light (PL) as well as synergy between the sanitizer wash and PL New formula sanitizers based on decontamination efficacy of single washing solutions (organic acids, hydrogen peroxide (H2O2), essential oil or surfactant) were applied to decontaminate spot inoculated green onions. PL, the novel technique, alone has been applied to inactivate Salmonella on both dip and spot inoculated green onions. Salmonella inactivation of PL-new formula sanitizer combinations on dip inoculated green onions was investigated for their potential synergy. As a result, for spot inoculated green onions, 0.4 mg/mL thymol individually and the five new formula sanitizers all achieved higher log reduction of Salmonella (4.5-5.3 log 10 CFU/g reduction) than the 200 ppm chlorine washing. These new formulas of sanitizer would be potential alternatives to chlorine. The 5 s dry PL (4.6 log 10 CFU/g) or 60 s wet PL treatment (3.6 log 10 CFU/g) was better or comparable as chlorine washing. The sanitizer combinations did not provide significantly higher log reduction than PL, and PL has the potential of being used in the green onion industry for decontamination purpose. For dip inoculated green onions, none of our treatment provided >0.8 log 10 CFU/g (0.6-0.8 log 10 CFU/g) reduction of Salmonella. As a result, the PL-new formula sanitizer combinations had no or minimal synergy to inactivate Salmonella dip inoculated on green onions. (C) 2014 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available