4.6 Article

Laminar flow and heat transfer through a circular tube having integral transverse corrugations and fitted with centre-cleared twisted-tape

Journal

EXPERIMENTAL THERMAL AND FLUID SCIENCE
Volume 57, Issue -, Pages 388-395

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.expthermflusci.2014.06.008

Keywords

Laminar flow; Forced convection; Integral transverse corrugations; Twisted tapes; Heat transfer enhancement; Swirl flow

Funding

  1. MHRD
  2. DST
  3. CSIR, Government of India

Ask authors/readers for more resources

The experimental friction factor and Nusselt number data for laminar flow through a circular duct having integral transverse corrugation and fitted with centre-cleared twisted-tape has been presented. Predictive friction factor and Nusselt number correlations have also been presented. The thermohydraulic performance has been evaluated. The major findings of this experimental investigation are that the centre-cleared twisted tapes in combination with integral transverse corrugation perform better than the individual enhancement technique acting alone for laminar flow through a circular duct up to a certain amount of twisted-tape centre-clearance. (C) 2014 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available