4.7 Article

Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla

Journal

EUROPEAN RADIOLOGY
Volume 23, Issue 11, Pages 2969-2978

Publisher

SPRINGER
DOI: 10.1007/s00330-013-2972-1

Keywords

High-field MRI; Fat suppression; Breast cancer; Bilateral breast imaging; RF coil array

Funding

  1. NIH [R01 EB002568]

Ask authors/readers for more resources

To evaluate the image quality of T1-weighted fat-suppressed breast MRI at 7 T and to compare 7-T and 3-T images. Seventeen subjects were imaged using a 7-T bilateral transmit-receive coil and 3D gradient echo sequence with adiabatic inversion-based fat suppression (FS). Images were graded on a five-point scale and quantitatively assessed through signal-to-noise ratio (SNR), fibroglandular/fat contrast and signal uniformity measurements. Image scores at 7 and 3 T were similar on standard-resolution images (1.1 x 1.1 x 1.1-1.6 mm(3)), indicating that high-quality breast imaging with clinical parameters can be performed at 7 T. The 7-T SNR advantage was underscored on 0.6-mm isotropic images, where image quality was significantly greater than at 3 T (4.2 versus 3.1, P a parts per thousand currency signaEuro parts per thousand 0.0001). Fibroglandular/fat contrast was more than two times higher at 7 T than at 3 T, owing to effective adiabatic inversion-based FS and the inherent 7-T signal advantage. Signal uniformity was comparable at 7 and 3 T (P < 0.05). Similar 7-T image quality was observed in all subjects, indicating robustness against anatomical variation. The 7-T bilateral transmit-receive coil and adiabatic inversion-based FS technique produce image quality that is as good as or better than at 3 T. aEuro cent High image quality bilateral breast MRI is achievable with clinical parameters at 7 T. aEuro cent 7-T high-resolution imaging improves delineation of subtle soft tissue structures. aEuro cent Adiabatic-based fat suppression provides excellent fibroglandular/fat contrast at 7 T. aEuro cent 7- and 3-T 3D T1-weighted gradient-echo images have similar signal uniformity. aEuro cent The 7-T dual solenoid coil enables bilateral imaging without compromising uniformity.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available