Frequency and predictors of endoleaks and long-term patency after covered stent placement for the treatment of intracranial aneurysms: a prospective, non-randomised multicentre experience
Published 2012 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Frequency and predictors of endoleaks and long-term patency after covered stent placement for the treatment of intracranial aneurysms: a prospective, non-randomised multicentre experience
Authors
Keywords
Intracranial aneurysm, Covered stent, Endoleak, In-stent stenosis, Multiple regression analysis
Journal
EUROPEAN RADIOLOGY
Volume 23, Issue 1, Pages 287-297
Publisher
Springer Nature
Online
2012-07-11
DOI
10.1007/s00330-012-2581-4
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Simple Measurement of Aneurysm Residual after Treatment: the SMART scale for evaluation of intracranial aneurysms treated with flow diverters
- (2011) Iris Quasar Grunwald et al. ACTA NEUROCHIRURGICA
- Immediate and Midterm Results following Treatment of Recently Ruptured Intracranial Aneurysms with the Pipeline Embolization Device
- (2011) W. McAuliffe et al. AMERICAN JOURNAL OF NEURORADIOLOGY
- Long-Term Follow-Up after Treatment of Intracranial Aneurysms with the Pipeline Embolization Device: Results from a Single Center
- (2011) H.A. Deutschmann et al. AMERICAN JOURNAL OF NEURORADIOLOGY
- Hemodynamics of Cerebral Aneurysm Initiation: The Role of Wall Shear Stress and Spatial Wall Shear Stress Gradient
- (2011) Z. Kulcsár et al. AMERICAN JOURNAL OF NEURORADIOLOGY
- Mural destabilization after aneurysm treatment with a flow-diverting device: a report of two cases
- (2011) T. Hampton et al. Journal of NeuroInterventional Surgery
- A Systematic Review of Stenting and Angioplasty of Symptomatic Extracranial Vertebral Artery Stenosis
- (2011) Aaron N. Stayman et al. STROKE
- Reply:
- (2010) J. Raymond et al. AMERICAN JOURNAL OF NEURORADIOLOGY
- Perforator Infarction after Placement of a Pipeline Flow-Diverting Stent for an Unruptured A1 Aneurysm: Fig 1.
- (2010) W.J. van Rooij et al. AMERICAN JOURNAL OF NEURORADIOLOGY
- Treatment of carotid siphon aneurysms by use of the Willis stent graft: an angiographic and histopathological study
- (2010) Yue-Qi Zhu et al. EUROPEAN RADIOLOGY
- Application of the Willis Covered Stent in the Treatment of Aneurysm in the Cisternal Segment of the Internal Carotid Artery: A Pilot Comparative Study With Midterm Follow-up
- (2010) Yue-Qi Zhu et al. JOURNAL OF ENDOVASCULAR THERAPY
- STENT GRAFT TREATMENT OF CEREBROVASCULAR WALL DEFECTS
- (2010) Daniel A. Hoit et al. Operative Neurosurgery
- Very Late Thrombosis of a Pipeline Embolization Device Construct
- (2010) David Fiorella et al. Operative Neurosurgery
- DEFINITIVE RECONSTRUCTION OF CIRCUMFERENTIAL, FUSIFORM INTRACRANIAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE
- (2009) David Fiorella et al. NEUROSURGERY
- CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE
- (2009) Pedro Lylyk et al. NEUROSURGERY
- Treatment of Distal Internal Carotid Artery Aneurysm with the Willis Covered Stent: A Prospective Pilot Study
- (2009) Ming-Hua Li et al. RADIOLOGY
- The Feasibility and Efficacy of Treatment with a Willis Covered Stent in Recurrent Intracranial Aneurysms after Coiling
- (2008) M.-H. Li et al. AMERICAN JOURNAL OF NEURORADIOLOGY
- Advances in Interventional Neuroradiology 2007
- (2008) David M. Pelz et al. STROKE