4.7 Article

Chemical sensing platform for the Zn+2 ions based on poly(o-anisidine-co-methyl anthranilate) copolymer composites and their environmental remediation in real samples

Journal

ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH
Volume 25, Issue 28, Pages 27899-27911

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s11356-018-2819-z

Keywords

Copolymer composites; Zn+2 cation sensor; I-V method; Sensitivity; Environmental safety; Bacteriostatic studies

Funding

  1. Center of Excellence for Advanced Materials Research, Chemistry Department, King Abdulaziz University, Jeddah, Saudi Arabia

Ask authors/readers for more resources

A novel nanostructure of poly(o-anisidine-co-methyl anthranilate) (poly(Ani-Co-MA) copolymer has been synthesized by chemical oxidative in situ polymerization technique with equal molar proportion of monomers in the presence of sodium dodecylbenzene sulfonic acid (SDBS) surfactant. The synthesized copolymers were characterized by scanning electron microscope (SEM) and X-ray crystallography (XRD), Fourier transform infrared (FTIR), UV-Vis, thermo-gravimetric analysis (TGA), and simultaneous X-ray photoelectron spectroscopy (XPS) study. The ultraviolet visible spectrum shows the to transition and n to transition. XRD diffraction pattern confirms the amorphous nature of poly(Ani-Co-MA)-SDBS composites. The scanning electron microscope image shows the morphology of the copolymer matrix. For the selective detection of Zn+2 cation in neutral phosphate buffer, it was fabricated Zn+2 cation sensor based on glassy carbon electrode (GCE) coated with poly(Ani-co-MA)-SDBS composites as a thin layer with conducting coating binders. The proposed cation sensor has been found to exhibit the inertness in air and chemical environment, long-term stability with good sensitivity, a broad linear dynamic range practically, a reliable reproducibility, short response time, and high electrochemical activity. The sensitivity (0.3560AM(-1)cm(-2)) of Zn+2 cation sensor has been calculated from the slope of the calibration curve. The linearity of the calibration curve is found over the linear dynamic range (LDR) 0.1nM similar to 0.01M, and detection limit (DL) is 27.01.35pM at the signal to noise ratio of 3. This novel effort may be considered quite reliable and effective to detect Zn+2 cation in environmental and biomedical sectors on a broad scale. Simultaneously, SDBS doped poly(o-anisidine-co-methyl anthranilate) copolymer composites were measured against medically important organisms Escherichia coli. E. ludwigi, and Bacillus subtilis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available