4.8 Article

Virus' (MS2, φX174, and Aichi) Attachment on Sand Measured by Atomic Force Microscopy and Their Transport through Sand Columns

Journal

ENVIRONMENTAL SCIENCE & TECHNOLOGY
Volume 44, Issue 7, Pages 2426-2432

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/es903221p

Keywords

-

Funding

  1. USDA Cooperative State Research, Education, and Extensive Services [2006-35102-17405]
  2. EPSCoR
  3. Office Of The Director [814251] Funding Source: National Science Foundation

Ask authors/readers for more resources

Atomic force microscopy (AFM) was used to study the attachment of phi X174, MS2, and Aichi viruses on sands of different surface properties: oxide-removed (clean), goethite-coated, and aluminum oxide-coated. Interaction forces between viruses and sand surfaces were measured by contact mode AFM using tips coated with particles of each virus. Column experiments were conducted to quantify the macroscopic transport and retention of the viruses in sand. The average adhesion force measured with AFM was highest between aluminum oxide-coated sand and all three viruses, followed by goethite-coated sand, and was significantly lower on oxide-removed sand. Among the viruses, adhesion on goethite-coated and aluminum oxide-coated sands followed the order of MS2 > Aichi > phi X174, and on oxide-removed sand it was phi X174 > Aichi > MS2. Column breakthrough results revealed the same retention trend, which was completely consistent with AFM force measurements. Strong electrostatic attraction and, to a lesser extent, hydrophobic interactions are responsible for the much greater removal of all three viruses observed in the oxide-coated sands compared to the oxide-removed sand. Mass recovery data indicate that the removal of phi X174, MS2, and Aichi was largely reversible when eluted with 3% beef extract solution at pH 9.5. The Derjaguin-Landau-Verwey-Overbeek (DLVO) and extended DLVO theories provided correct qualitative predictions on the deposition trend observed in the experiments. This study, to the best of our knowledge, was the first to employ AFM to directly measure interaction forces between viruses and solid surfaces; and it was the first to evaluate the retention and transport behavior of Aichi virus, a human pathogen.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available