Journal
ENERGY CONVERSION AND MANAGEMENT
Volume 49, Issue 6, Pages 1612-1619Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.enconman.2007.12.001
Keywords
heat pump; solar drying; evaporator-collector; air collector; performance of collectors
Categories
Ask authors/readers for more resources
A solar assisted heat pump dryer has been designed, fabricated and tested. This paper presents the performance of the evaporator-collector and the air collector when operated under the same meteorological conditions. ASHRAE standard procedure for collector testing has been followed. The evaporator-col lector of the heat pump is acting directly as the solar collector, and the temperature of the refrigerant at the inlet to the evaporator-col lector always remained below the ambient temperature. Because of the rejection of sensible and latent heats of air at the dehumidifier, the temperature at the inlet to the air collector is lower than that of the ambient air. Hence, the thermal efficiency of the air collector also increases due to a reduction of losses from the collector. The efficiencies of the evaporator-collector and the air collector were found to vary between 0.8-0.86 and 0.7-0.75, respectively, when operated under the meteorological conditions of Singapore. (C) 2007 Elsevier Ltd. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews