4.7 Article

Combustion and NOx emissions characteristics of a down-fired 660-MWe utility boiler retro-fitted with air-surrounding-fuel concept

Journal

ENERGY
Volume 36, Issue 1, Pages 70-77

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2010.11.010

Keywords

Air-surrounding-fuel; Down-fired boiler; NOx emission

Funding

  1. Hi-Tech Research and Development Program of China (863 Program) [2006AA05Z321]

Ask authors/readers for more resources

Air-surrounding-fuel is a well-known concept used within tangential and wall-fired boilers. Here, we report for the first time on industrial experiments performed to study the effects of this concept on a 660 MWe full-scale down-fired boiler. Data are reported for the gas temperature distributions along the primary air and coal-mixed flows, furnace temperatures, gas compositions for example O-2, CO and NOx, and gas temperatures in the near-wall region. The influence of concentration control valve (CCV) opening on combustion and NOx emission in the furnace were determined. The results show that the flame stability, temperature distribution, unburnt carbon are influenced by both concentration ratios and fuel-rich flow velocities. As CCV opening increases, NOx emissions decrease from 2594 mg/m(3) to 1895 mg/m(3). Considering altogether economic benefits and environmental protection issues, 30% is the optimal value for the CCV opening. (C) 2010 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available