4.0 Article

Response properties of electrically evoked potential elicited by multi-channel penetrative optic nerve stimulation in rabbits

Journal

DOCUMENTA OPHTHALMOLOGICA
Volume 118, Issue 3, Pages 191-204

Publisher

SPRINGER
DOI: 10.1007/s10633-008-9157-2

Keywords

Electrically evoked potential (EEP); Multi-electrode array; Rabbit; Optic nerve stimulation; Response properties; Visual prosthesis

Categories

Funding

  1. National Basic Research Program of China [2005CB724302]
  2. National Natural Science Foundation of China [60588101, 60871091]
  3. Shanghai Pujiang Program [07PJ14050]
  4. National High Technology Research and Development Program of China [2006AA04Z356]
  5. Shanghai Commission of Science and Technology [064119540]

Ask authors/readers for more resources

Visual prosthesis is a potential way to restore partial vision for the patients with degenerative retinal diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD). Optic nerve stimulation with penetrating microelectrode array has been suggested as a possible method for visual prosthesis. The purpose of this study was to investigate the feasibility and basic response properties of cortical responses elicited by optic nerve stimulation with penetrating electrodes in rabbits. In this study, three triangularly or linearly configured platinum-iridium wire electrodes were inserted into the optic nerves of rabbits for electrical stimulation. The charge-balanced current pulses with amplitudes ranging from 10 to 100 mu A at 0.5 ms pulse duration were used as the electrical stimuli. The electrically evoked potentials (EEPs) were recorded with a 16-channel silver-ball electrode array in the rabbit visual cortex. Our experimental results showed that the activities of visual cortex could be effectively evoked by the optic nerve stimulation with penetrating electrodes. The threshold of current and charge density to elicit EEPs under optic nerve stimulation at 0.5 ms pulse duration was 20.3 +/- A 7.5 mu A and 37.8 +/- A 13.9 mu C/cm(2), respectively. Current stimuli with cathode-first pulses elicited larger cortical responses than that with anode-first pulses. The amplitude of P1 and extent of EEPs increased as the stimulating current amplitude increased, while the latency of P1 decreased. The spatial distributions of multi-channel EEPs in visual cortex demonstrated distinctively different properties under stimulation with different orientations of the stimulating electrodes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available