Safety of Nighttime 2-Hour Suspension of Basal Insulin in Pump-Treated Type 1 Diabetes Even in the Absence of Low Glucose
Published 2013 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Safety of Nighttime 2-Hour Suspension of Basal Insulin in Pump-Treated Type 1 Diabetes Even in the Absence of Low Glucose
Authors
Keywords
-
Journal
DIABETES CARE
Volume 37, Issue 3, Pages 773-779
Publisher
American Diabetes Association
Online
2013-10-30
DOI
10.2337/dc13-1608
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Effect of Sensor-Augmented Insulin Pump Therapy and Automated Insulin Suspension vs Standard Insulin Pump Therapy on Hypoglycemia in Patients With Type 1 Diabetes
- (2013) Trang T. Ly et al. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION
- Threshold-Based Insulin-Pump Interruption for Reduction of Hypoglycemia
- (2013) Richard M. Bergenstal et al. NEW ENGLAND JOURNAL OF MEDICINE
- Analysis of Glucose Responses to Automated Insulin Suspension With Sensor-Augmented Pump Therapy
- (2012) T. T. Ly et al. DIABETES CARE
- Blood Glucose Control in Type 1 Diabetes With a Bihormonal Bionic Endocrine Pancreas
- (2012) S. J. Russell et al. DIABETES CARE
- Effect of Pramlintide on Prandial Glycemic Excursions During Closed-Loop Control in Adolescents and Young Adults With Type 1 Diabetes
- (2012) S. A. Weinzimer et al. DIABETES CARE
- Feasibility Study of Automated Overnight Closed-Loop Glucose Control Under MD-Logic Artificial Pancreas in Patients with Type 1 Diabetes: The DREAM Project
- (2012) Revital Nimri et al. Diabetes Technology & Therapeutics
- Reduction in Duration of Hypoglycemia by Automatic Suspension of Insulin Delivery: The In-Clinic ASPIRE Study
- (2012) Satish Garg et al. Diabetes Technology & Therapeutics
- Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia: Reduction in nocturnal hypoglycemia in those at greatest risk
- (2011) P. Choudhary et al. DIABETES CARE
- Fear of Hypoglycemia in Type 1 Diabetes Managed by Continuous Subcutaneous Insulin Infusion: Is It Associated with Poor Glycemic Control?
- (2011) Rodanthe Nixon et al. Diabetes Technology & Therapeutics
- Prevention of Hypoglycemia by Using Low Glucose Suspend Function in Sensor-Augmented Pump Therapy
- (2011) Thomas Danne et al. Diabetes Technology & Therapeutics
- Prolonged Nocturnal Hypoglycemia Is Common During 12 Months of Continuous Glucose Monitoring in Children and Adults With Type 1 Diabetes
- (2010) DIABETES CARE
- Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes
- (2010) J. R. Castle et al. DIABETES CARE
- Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial
- (2010) Roman Hovorka et al. LANCET
- A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
- (2010) F. H. El-Khatib et al. Science Translational Medicine
- Closed-Loop Insulin Delivery Using a Subcutaneous Glucose Sensor and Intraperitoneal Insulin Delivery: Feasibility study testing a new model for the artificial pancreas
- (2009) E. Renard et al. DIABETES CARE
- Duration of Nocturnal Hypoglycemia Before Seizures
- (2008) B. Buckingham et al. DIABETES CARE
- Fully Automated Closed-Loop Insulin Delivery Versus Semiautomated Hybrid Control in Pediatric Patients With Type 1 Diabetes Using an Artificial Pancreas
- (2008) S. A. Weinzimer et al. DIABETES CARE
- Continuous Glucose Monitoring and Intensive Treatment of Type 1 Diabetes
- (2008) NEW ENGLAND JOURNAL OF MEDICINE