4.2 Article

Determination of asymmetric dimethylarginine in biological fluids: a paradigm for a successful analytical story

Journal

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MCO.0b013e3283065bb1

Keywords

comparison; liquid chromatography; mass spectrometry; quantification; validation

Ask authors/readers for more resources

Purpose of review To review recently reported analytical methods for the quantification in biological fluids of asymmetric dimethylarginine, an endogenous inhibitor of nitric oxide synthesis, and to evaluate their impact on clinical research. Recent findings Recently developed and increasingly used analytical methods in this area are based on mass spectrometry coupled with gas chromatography (i.e., gas chromatography-mass spectrometry and gas chromatography-mass spectrometry/mass spectrometry) or liquid chromatography (i.e., liquid chromatography-mass spectrometry and liquid chromatography-mass spectrometry/mass spectrometry). These approaches revealed asymmetric dimethylarginine concentrations in plasma and serum of healthy adults in the range 400-500 nmol/l. High-performance liquid chromatography methods with fluorescence detection provide asymmetric dimethylarginine plasma/serum concentrations comparable to those of mass spectrometry-based methods. This interval for circulating asymmetric dimethylarginine and the mass spectrometry/mass spectrometry-based methods have the potential to serve as reference values and analytical methods, respectively. An enzyme-linked immunosorbent assay method for asymmetric dimethylarginine has become commercially available and is increasingly used in clinical studies. Comparative studies revealed that the enzyme-linked immunosorbent assay method produces considerably higher asymmetric dimethylarginine concentrations in plasma or serum in healthy humans in the basal state than mass spectrometry and high-performance liquid chromatography methods and runs varyingly in different laboratories. Summary At present, many analytical methods allow for the accurate and precise quantification of asymmetric dimethylarginine in biological fluids. However, reliable quantification of biological asymmetric dimethylarginine remains an analytical challenge in basic and clinical research.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available