4.4 Article

Method for Expressing Clinical and Statistical Significance of Ocular and Corneal Wave Front Error Aberrations

Journal

CORNEA
Volume 31, Issue 3, Pages 212-221

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/ICO.0b013e318221ce7d

Keywords

corneal topography; Zernike polynomial; wave front error; ocular aberrations; corneal aberrations

Categories

Funding

  1. National Eye Institute from the National Institutes of Health, Bethesda, MD [R01EY014162]
  2. Research to Prevent Blindness, New York, NY
  3. Louisiana State University School of Medicine

Ask authors/readers for more resources

Purpose: The significance of ocular or corneal aberrations may be subject to misinterpretation whenever eyes with different pupil sizes or the application of different Zernike expansion orders are compared. A method is shown that uses simple mathematical interpolation techniques based on normal data to rapidly determine the clinical significance of aberrations, without concern for pupil and expansion order. Methods: Corneal topography maps (TOMEY, Inc, Nagoya, Japan) from 30 normal corneas were collected, and the corneal wave front error was analyzed by Zernike polynomial decomposition into specific aberration types for pupil diameters of 3, 5, 7, and 10 mm and Zernike expansion orders of 6, 8, 10, and 12. Using this 4 3 4 matrix of pupil sizes and fitting orders, the best-fitting 3-dimensional functions were determined for the mean and standard deviation of the root-mean-square error for specific aberrations. The functions were encoded into a software application to determine the significance of data acquired from nonnormal cases. Results: The best-fitting functions for 6 types of aberrations were determined: defocus, astigmatism, prism, coma, spherical aberration, and all higher-order aberrations. A clinical screening method of color coding the significance of aberrations in normal, postoperative laser in situ keratomileusis, and keratoconus cases having different pupil sizes and different expansion orders is demonstrated. Conclusions: A method to calibrate wave front aberrometry devices using a standard sample of normal cases was devised. This method could be potentially useful in clinical studies involving patients with uncontrolled pupil sizes or in studies that compare data from aberrometers that use different Zernike fitting-order algorithms.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available