4.4 Article

Right Ventricular Outflow Tract Repair with a Cardiac Biologic Scaffold

Journal

CELLS TISSUES ORGANS
Volume 195, Issue 1-2, Pages 159-170

Publisher

KARGER
DOI: 10.1159/000331400

Keywords

Heart defects, congenital; Tissue engineering; Surgery; Myocardium; Remodeling

Funding

  1. NIH [R03 EB009237-01, T32 HL76124]
  2. NIH-NIBIB [1R03EB009237-01A1]
  3. NIH-NHLBI [T32-HL76124]
  4. NATIONAL CENTER FOR ADVANCING TRANSLATIONAL SCIENCES [UL1TR000005] Funding Source: NIH RePORTER
  5. NATIONAL CENTER FOR RESEARCH RESOURCES [UL1RR024153] Funding Source: NIH RePORTER
  6. NATIONAL HEART, LUNG, AND BLOOD INSTITUTE [T32HL076124] Funding Source: NIH RePORTER
  7. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R03EB009237] Funding Source: NIH RePORTER

Ask authors/readers for more resources

Background: Surgical reconstruction of congenital heart defects is often limited by the nonresorbable material used to approximate normal anatomy. In contrast, biologic scaffold materials composed of resorbable non-cross-linked extracellular matrix (ECM) have been used for tissue reconstruction of multiple organs and are replaced by host tissue. Preparation of whole organ ECM by decellularization through vascular perfusion can maintain much of the native three-dimensional (3D) structure, strength, and tissue-specific composition. A 3D cardiac ECM (C-ECM) biologic scaffold material would logically have structural and functional advantages over materials such as Dacron (TM) for myocardial repair, but the in vivo remodeling characteristics of C-ECM have not been investigated to date. Methods and Results: A porcine C-ECM patch or Dacron patch was used to reconstruct a full-thickness right ventricular outflow tract (RVOT) defect in a rat model with end points of structural remodeling function at 16 weeks. The Dacron patch was encapsulated by dense fibrous tissue and showed little cellular infiltration. Echocardiographic analysis showed that the right ventricle of the hearts patched with Dacron were dilated at 16 weeks compared to presurgery baseline values. The C-ECM patch remodeled into dense, cellular connective tissue with scattered small islands of cardiomyocytes. The hearts patched with C-ECM showed no difference in the size or function of the ventricles as compared to baseline values at both 4 and 16 weeks. Conclusions: The C-ECM patch was associated with better functional and histomorphological outcomes compared to the Dacron patch in this rat model of RVOT reconstruction. Copyright (C) 2011 S. Karger AG, Basel

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available