4.7 Article

Ultra high performance liquid chromatography coupled to tandem mass spectrometry determination of lipid peroxidation biomarkers in newborn serum samples

Journal

ANALYTICA CHIMICA ACTA
Volume 886, Issue -, Pages 214-220

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2015.06.028

Keywords

Isoprostanes; Liquid chromatography; Mass spectrometry; Serum; Newborn; Oxidative stress

Funding

  1. Carmen & Severo Ochoa Grant (City Government
  2. Valencia)
  3. Health Institute Carlos III (Spanish Ministry of Economy and Competitiveness) [FIS PI14/0443, RD12/0026/0012]
  4. 'Sara Borrell' grant from the Health Institute Carlos III (Spanish Ministry of Economy and Competitiveness) [CD12/00667]
  5. Red de Salud Materno Infantil (SAMID)

Ask authors/readers for more resources

Byproducts of arachidonic (AA) and docosahexaenoic acid (DHA) oxidation are highly relevant for the study of free radical associated conditions in the perinatal period. Plasma metabolites can provide the clinician with a snapshot of the oxidant status of patients before and after specific clinical interventions (e.g.: supplementation with oxygen). We describe a new andreliable ultra-performance liquid mass spectrometry method to determine F2-isoprostanes and other byproducts (isoprostanes, isofurans, neuroprostanes, neurofurans) in newborn serum samples. Cord blood samples were obtained from severely depressed newborn infants (Apgar score 1 min < 3; arterial cord pH < 7.00), and aliquoted for serum determination and stored at -80 degrees C. AUHPLC-MS/MS method was employed. It has a series of technical advantages: simple sample treatment; reduced sample volume (100 mu L) which is essential for preterm neonates with low circulating blood volume, high throughput of sample analysis (96 samples in less than 24 h) and high selectivity for different isoprostanes isomers. Excellent sensitivity was achieved within limits of detection between 0.06 and 4.2 nmol L-1, which renders this method suitable to monitoranalyte concentration in newborn samples. The method's precision was satisfactory; with coefficients of variation around 5-12% (intra-day) and 7-17% (inter-day). The reliability of the described method was assessed by analysis of spiked serum samples obtaining recoveries between 70% and 120%. The proposed method has rendered suitable for serum determination for newborn babies at risk of oxygen free radical associated conditions. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available