4.8 Article Proceedings Paper

Error analysis of thermal response tests

Journal

APPLIED ENERGY
Volume 109, Issue -, Pages 302-311

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2012.11.060

Keywords

Thermal response test; Ground thermal conductivity; Borehole resistance; Error analysis; Infinite line source; Borehole heat exchanger

Ask authors/readers for more resources

The ground thermal conductivity and borehole thermal resistance are essential parameters for the design of a ground source heat pump system. As it is hardly possible to obtain sufficiently accurate values of these parameters from geological or soil-profile information, thermal response tests have been developed that provide measurements in situ. These tests have become part of the standard toolkit of the shallow geothermal energy systems engineer, but a systematic evaluation of the different sources of uncertainty (error) and their effect on the quality of the result is lacking. This paper explores the different error sources and shows how they contribute to the final overall error in estimated thermal properties. The results show that the theoretical errors are expected to be on the order of 5% for the soil thermal conductivity and 10-15% for the borehole resistance. The largest contributions to the error of the thermal conductivity are the measured temperature difference, fluid heat capacity and slope of the regression coefficient. The borehole resistance error is mainly influenced by the error of thermal conductivity. (C) 2012 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available