4.6 Article

An Increase in Aortic Blood Flow after an Infusion of 100 ml Colloid over 1 Minute Can Predict Fluid Responsiveness The Mini-fluid Challenge Study

Journal

ANESTHESIOLOGY
Volume 115, Issue 3, Pages 541-547

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/ALN.0b013e318229a500

Keywords

-

Categories

Ask authors/readers for more resources

Background: Predicting fluid responsiveness remains a difficult question in hemodynamically unstable patients. The author's objective was to test whether noninvasive assessment by transthoracic echocardiography of subaortic velocity time index (VTI) variation after a low volume of fluid infusion (100 ml hydroxyethyl starch) can predict fluid responsiveness. Methods: Thirty-nine critically ill ventilated and sedated patients with acute circulatory failure were prospectively studied. Subaortic VTI was measured by transthoracic echocardiography before fluid infusion (baseline), after 100 ml hydroxyethyl starch infusion over 1 min, and after an additional infusion of 400 ml hydroxyethyl starch over 14 min. The authors measured the variation of VTI after 100 ml fluid (Delta VTI100) for each patient. Receiver operating characteristic curves were generated for (Delta VTI100). When available, receiver operating characteristic curves also were generated for pulse pressure variation and central venous pressure. Results: After 500 ml volume expansion, VTI increased >= 15% in 21 patients (54%) defined as responders. Delta VTI100 >= 10% predicted fluid responsiveness with a sensitivity and specificity of 95% and 78%, respectively. The area under the receiver operating characteristic curves of Delta VTI100 was 0.92 (95% CI: 0.78-0.98). In 29 patients, pulse pressure variation and central venous pressure also were available. In this subgroup of patients, the area under the receiver operating characteristic curves for Delta VTI100, pulse pressure variation, and central venous pressure were 0.90 (95% CI: 0.74-0.98, P < 0.05), 0.55 ( 95% CI: 0.35-0.73, NS), and 0.61 ( 95% CI: 0.41-0.79, NS), respectively. Conclusion: In patients with low volume mechanical ventilation and acute circulatory failure, Delta VTI100 accurately predicts fluid responsiveness.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available