4.7 Article

Determination of filbertone in spiked olive oil samples using headspace-programmed temperature vaporization-gas chromatography-mass spectrometry

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 394, Issue 5, Pages 1463-1470

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-009-2795-8

Keywords

Olive oil; Filbertone; Programmed temperature vaporizers

Funding

  1. DGI [CTQ2007-63157/BQU]
  2. Consejeria de Educacion y Cultura of the Junta de Castilla y Leon [SA112A08]

Ask authors/readers for more resources

A sensitive method for the fast analysis of filbertone in spiked olive oil samples is presented. The applicability of a headspace (HS) autosampler in combination with a gas chromatograph (GC) equipped with a programmable temperature vaporizer (PTV) and a mass spectrometric (MS) detector is explored. A modular accelerated column heater (MACHTM) was used to control the temperature of the capillary gas chromatography column. This module can be heated and cooled very rapidly, shortening total analysis cycle times to a considerable extent. The proposed method does not require any previous analyte extraction, filtration and preconcentration step, as in most methods described to date. Sample preparation is reduced to placing the olive oil sample in the vial. This reduces the analysis time and the experimental errors associated with this step of the analytical process. By using headspace generation, the volatiles of the sample are analysed without interference by the non-volatile matrix, and by using injection in solvent-vent mode at the PTV inlet, most of the compounds that are more volatile than filbertone are purged and the matrix effect is minimised. Use of a liner packed with Tenax-TA (R) allowed the compound of interest to be retained during the venting process. The limits of detection and quantification were as low as 0.27 and 0.83 mu g/L, respectively, and precision (measured as the relative standard deviation) was 5.7%. The method was applied to the determination of filbertone in spiked olive oil samples and the results revealed the good accuracy obtained with the method.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

Review Chemistry, Analytical

Non-separative mass spectrometry methods for non-invasive medical diagnostics based on volatile organic compounds: A review

Ana Maria Casas-Ferreira, Miguel del Nogal-Sanchez, Jose Luis Perez-Pavon, Bernardo Moreno-Cordero

ANALYTICA CHIMICA ACTA (2019)

Biographical-Item Biochemical Research Methods

In honor of Professor Alfredo Sanz-Medel

Jose Luis Perez-Pavon, Elena Dominguez Canas

ANALYTICAL AND BIOANALYTICAL CHEMISTRY (2019)

Article Biochemical Research Methods

Multiple headspace sampling coupled to a programmed temperature vaporizer to improve sensitivity in headspace-gas chromatography. Determination of aldehydes

Javier Pena, Ma Esther Fernandez Laespada, Carmelo Garcia Pinto, Jose Luis Perez Pavon, Bernardo Moreno Cordero

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES (2019)

Article Chemistry, Analytical

A sensitive and automatic method based on microextraction by packed sorbents for the determination of polycyclic aromatic hydrocarbons in saliva samples

Patricia Martin Santos, Camilo Jimenez Carracedo, Miguel del Nogal Sanchez, Jose Luis Perez Pavon, Bernardo Moreno Cordero

MICROCHEMICAL JOURNAL (2020)

Article Chemistry, Analytical

Non-separative method based on a single quadrupole mass spectrometer for the semi-quantitative determination of amino acids in saliva samples. A preliminary study

Patricia Martin Santos, Miguel del Nogal Sanchez, Jose Luis Perez Pavon, Bernardo Moreno Cordero

TALANTA (2020)

Article Chemistry, Analytical

Determination of leucine and isoleucine/allo-isoleucine by electrospray ionization-tandem mass spectrometry and partial least square regression: Application to saliva samples

Ana Maria Casas-Ferreira, Miguel del Nogal-Sanchez, Encarnacion Rodriguez-Gonzalo, Bernardo Moreno-Cordero, Jose Luis Perez-Pavon

TALANTA (2020)

Article Geochemistry & Geophysics

Layered Double Hydroxides with Intercalated Permanganate and Peroxydisulphate Anions for Oxidative Removal of Chlorinated Organic Solvents Contaminated Water

Karen Maria Dietmann, Tobias Linke, Miguel del Nogal Sanchez, Jose Luis Perez Pavon, Vicente Rives

MINERALS (2020)

Article Chemistry, Analytical

Multiple headspace sampling coupled to a programmed temperature vaporizer - Gas chromatograph-mass spectrometer for the determination of polycyclic aromatic hydrocarbons in water and saliva

Javier Pena, Ma Esther Fernandez Laespada, Carmelo Garcia Pinto, Jose Luis Perez Pavon

Summary: A multiple headspace sampling methodology coupled to a programmed temperature vaporizer and a gas chromatograph-mass spectrometer was developed for the determination of PAHs. The method was successfully validated in water and saliva, showing low detection limits and good linear behavior. Different repeatability values and changes were observed in water and saliva samples, with varying concentrations.

MICROCHEMICAL JOURNAL (2021)

Article Environmental Sciences

Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography-Mass Spectrometry

Samuel Garcia-Garcia, Hector Matilla-Gonzalez, Javier Pena, Miguel del Nogal Sanchez, Ana Maria Casas-Ferreira, Jose Luis Perez Pavon

Summary: A fast methodology for the determination of monohydroxy polycyclic aromatic hydrocarbons in human urine using a fully automated microextraction by packed sorbent coupled to a gas chromatograph-mass spectrometer has been developed and successfully applied. The method is simple and allows for high throughput analysis, with good accuracy and precision. Significant differences were found between urine samples from smokers and non-smokers, indicating the potential applicability of the method for studying exposure to these compounds.

INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH (2022)

Article Biochemical Research Methods

Use of a guard column coupled to mass spectrometry as a fast semi-quantitative methodology for the determination of plasticizer metabolites in urine

Iria Gonzalez-Marino, Ana Maria Casas-Ferreira, Miguel del Nogal Sanchez, Jose Luis Perez Pavon

Summary: A simple and fast method combining the use of a guard column-MS/MS was proposed for the determination of plasticizer metabolites in urine. The method showed high precision and low limits of quantification. It can analyze a large number of samples in a short time and achieves good agreement with UHPLC-MS/MS method.

JOURNAL OF CHROMATOGRAPHY A (2023)

Article Chemistry, Analytical

Development of a fast and reliable methodology for the determination of polyamines in urine by using a guard column as a low-resolution fractioning step prior to mass spectrometry. Comparison with flow injection-mass spectrometry analysis

Maria Teresa Fernandez-del-Campo-Garcia, Ana Maria Casas-Ferreira, Encarnacion Rodriguez-Gonzalo, Bernardo Moreno-Cordero, Jose Luis Perez-Pavon

MICROCHEMICAL JOURNAL (2020)

No Data Available