4.7 Article

Optofluidics-based DNA structure-competitive aptasensor for rapid on-site detection of lead(II) in an aquatic environment

Journal

ANALYTICA CHIMICA ACTA
Volume 849, Issue -, Pages 43-49

Publisher

ELSEVIER
DOI: 10.1016/j.aca.2014.08.015

Keywords

Lead ions; Functional DNA; Optofluidics; Aptasensor; G4 aptamer

Funding

  1. National Natural Science Foundation of China [21077063, 21277173]
  2. National Instrument Major Project of China [2012YQ3011105]
  3. Basic Research funds in Renmin University of China from the Central Government [13XNLJ01]

Ask authors/readers for more resources

Lead ions (Pb2+), ubiquitous and one of the most toxic metallic pollutants, have attracted increasing attentions because of their various neurotoxic effects. Pb2+ has been proven to induce a conformational change in G-quadruplex (G4) aptamers to form a stabilizing G4/Pb2+ complex. Based on this principle, an innovative optofluidics-based DNA structure-competitive aptasensor was developed for Pb2+ detection in an actual aquatic environment. The proposed sensing system has good characteristics, such as high sensitivity and selectivity, reusability, easy operation, rapidity, robustness, portability, use of a small sample volume, and cost effectiveness. A fluorescence-labeled G4 aptamer was utilized as a molecular probe. A DNA probe, a complementary strand of G4 aptamer, was immobilized onto the sensor surface. When the mixture of Pb2+ solution and G4 aptamer was introduced into the optofluidic cell, Pb2+ and the DNA probe bound competitively with the G4 aptamer. A high Pb2+ concentration reduced the binding of the aptamer and the DNA probe; thus, a low-fluorescence signal was detected. A sensitive sensing response to Pb2+ in the range of 1.0-300.0 nM with a low detection limit of 0.22 nM was exhibited under optimal conditions. The potential interference of the environmental sample matrix was assessed with spiked samples, and the recovery of Pb2+ ranged from 80 to 105% with a relative standard deviation value of <8.5%. These observations clearly illustrate that with the use of different DNA or aptamer probes, the sensing strategy presented can be easily extended to the rapid on-site monitoring of other trace analytes. (C) 2014 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available