4.6 Article

A 7-Year Prospective, Randomized, Clinical, and Radiographic Study After Arthroscopic Bankart Reconstruction Using 2 Different Types of Absorbable Tack

Journal

AMERICAN JOURNAL OF SPORTS MEDICINE
Volume 37, Issue 10, Pages 1930-1937

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1177/0363546509335197

Keywords

randomized long-term follow-up; shoulder dislocation; absorbable implants; arthroscopic Bankart reconstruction; radiographs

Funding

  1. Swedish Center for Research in Sports
  2. Western Sweden County Council Research Fund

Ask authors/readers for more resources

Background: Recent studies have shown that techniques for arthroscopic Bankart reconstruction using suture anchors or tacks can equal the results after an open procedure in the treatment of posttraumatic, recurrent, unidirectional shoulder instability. Which kind of technique and which implants to be used still need further study. Purpose: The aim of this study was to compare the clinical and radiographic results after arthroscopic Bankart reconstruction using 2 different types of absorbable implants. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: A randomized series of 40 patients who had recurrent shoulder instability underwent reconstruction involving either polygluconate-B polymer or self-reinforced poly-L-lactic acid polymer tack implants. The patients underwent radiographic and clinical assessments preoperatively and at 7 years. Blood levels of C-reactive protein were analyzed preoperatively and postoperatively. Results: The radiographic visibility of the drill holes was significantly (P=.0001) greater in the poly-L-lactic acid polymer group than in the polygluconate-B polymer group. The failure rate in terms of stability was 5 of 36 (14%) after 7 years and, as previously reported by Magnusson et al, 2 of 40 (5%) after 2 years. Analyses preoperatively and postoperatively of C-reactive protein revealed no significant difference between the groups. No significant differences were found between the groups in terms of strength in abduction, range of motion, and Rowe or Constant scores. Conclusion: Seven years after Bankart repair using either implant, the overall clinical results were satisfactory. The visibility of the drill holes was significantly greater after using poly-L-lactic acid polymer implants.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available