4.4 Article

Relation Between Digital Peripheral Arterial Tonometry and Brachial Artery Ultrasound Measures of Vascular Function in Patients With Coronary Artery Disease and in Healthy Volunteers

Journal

AMERICAN JOURNAL OF CARDIOLOGY
Volume 109, Issue 5, Pages 651-657

Publisher

EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC
DOI: 10.1016/j.amjcard.2011.10.023

Keywords

-

Funding

  1. American Heart Association (Dallas, Texas)
  2. North Carolina Translational and Clinical Services Institute (Chapel Hill, North Carolina)
  3. National Institutes of Health/National Center for Research Resources (Bethesda, Maryland) [M01RR00046, ULIRR025747]

Ask authors/readers for more resources

Digital peripheral arterial tonometry (PAT) is an emerging, noninvasive method to assess vascular function. The physiology underlying this phenotype, however, remains unclear. Therefore, we evaluated the relation between digital PAT and established brachial artery ultrasound measures of vascular function under basal conditions and after reactive hyperemia. Using a cross-sectional study design, digital PAT and brachial artery ultrasonography with pulsed wave Doppler were simultaneously completed at baseline and after reactive hyperemia in both those with established coronary artery disease (n = 99) and healthy volunteers with low cardiovascular disease risk (n = 40). Under basal conditions, the digital pulse volume amplitude demonstrated a significant positive correlation with the brachial artery velocity-time integral that was independent of the arterial diameter, in both the healthy volunteer (r(s) = 0.64, p <0.001) and coronary artery disease (r(s) = 0.63, p <0.001) cohorts. Similar positive relations were observed with the baseline brachial artery blood flow velocity and blood flow. In contrast, no relation between the reactive hyperemia-evoked digital PAT ratio and either brachial artery flow-mediated dilation or shear stress was observed in either cohort (p = NS). In conclusion, these findings demonstrate that the digital PAT measures of vascular function more closely reflect basal blood flow in the brachial artery than reactive hyperemia-induced changes in the arterial diameter or flow velocity, and the presence of vascular disease does not modify the physiology underlying the digital PAT phenotype. (C) 2012 Elsevier Inc. All rights reserved. (Am J Cardiol 2012;109:651-657)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available