4.5 Article Proceedings Paper

Causes of near misses in critical care of neonates and children

Journal

ACTA PAEDIATRICA
Volume 97, Issue 3, Pages 299-303

Publisher

BLACKWELL PUBLISHING
DOI: 10.1111/j.1651-2227.2007.00616.x

Keywords

almost adverse events; environment factors; human factors; medical errors; potential adverse events; system factors

Categories

Ask authors/readers for more resources

Aim: The primary goal of this study was to examine the nature and causes of medical errors known as almost adverse events (AAEs) and potential adverse events (PAEs) in intensive care units. Methods: Observations were conducted in the Neonatal Intensive Care Unit and in the Pediatric Intensive Care Unit in a large hospital in Israel. The AAEs and PAEs were classified into three main categories: environmental, system and human factors. Data encoding and analysis was based on a Bayesian model previously developed to analyse causes of traffic accidents, and the categories were based on systems and ergonomics approaches. Results: 'Workload' (a system factor) was the main cause of AAEs and 'communication failures' (a human factor) was the second main cause of AAEs. Among the environmental factors, 'failures in medical devices' was the most cited cause of AAEs. Environmental factors accounted for most of PAEs and among them 'form failures' was the most 'AAE'-prone factor.