4.5 Article

Long-term safety of bioresorbable scaffolds: insights from a network meta-analysis including 91 trials

Journal

EUROINTERVENTION
Volume 13, Issue 16, Pages 1904-1913

Publisher

EUROPA EDITION
DOI: 10.4244/EIJ-D-17-00646

Keywords

bare metal stent; bioresorbable scaffolds; drug-eluting stent; stent thrombosis

Ask authors/readers for more resources

Aims: The aim of this study was to investigate the long-term safety and efficacy of biodegradable scaffolds and metallic stents. Methods and results: We analysed a total of 91 randomised controlled trials with a mean follow-up of 3.7 years in 105,842 patients which compared two or more coronary metallic stents or biodegradable scaffolds and reported the long-term clinical outcomes (>= 2 years). Network meta-analysis showed that patients treated with the Absorb bioresorbable vascular scaffold (BVS) had a significantly higher risk of definite or probable scaffold thrombosis (ScT) compared to those treated with metallic DES. The risk of very late ScT was highest with the Absorb BVS among comparators. Pairwise conventional meta-analysis demonstrated that the elevated risk of ScT with Absorb BVS compared to cobalt-chromium everolimus-eluting stents was consistent across the time points of <= 30 days (early), 31 days - 1 year (late) and >1 year (very late) ScT. In addition, target lesion failure rates were significantly higher in the Absorb BVS cohort, driven by both increased risk of target vessel myocardial infarction and ischaemia-driven target lesion revascularisation. Conclusions: Absorb BVS implantation was associated with increased risk of long-term and very late ScT compared to current-generation metallic DES. The risk of ScT occurred with a rising trend beyond one year.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available