4.1 Article

Dynamics of Breakdown in a Low-Pressure Argon-Mercury Mixture in a Long Discharge Tube

Journal

PLASMA PHYSICS REPORTS
Volume 44, Issue 3, Pages 345-358

Publisher

MAIK NAUKA/INTERPERIODICA/SPRINGER
DOI: 10.1134/S1063780X18030054

Keywords

-

Funding

  1. Russian Foundation for Basic Research [15-02-06191]

Ask authors/readers for more resources

Breakdown dynamics in the course of glow discharge ignition in a long discharge tube (80 cm in length and 25 mm in diameter) filled with argon at a pressure of 3-4 Torr and mercury vapor at room temperature was studied experimentally. Rectangular voltage pulses with amplitudes from 1 to 2.5 kV were applied to the tube anode, the cathode being grounded. Complex electrical and optical measurements of the breakdown dynamics were carried out. Breakdown begins with a primary discharge between the anode and the tube wall. In this stage, a jump in the anode current and a sharp decrease in the anode voltage are observed and prebreakdown ionization wave arises near the anode. The cathode current appears only after the ionization wave reaches the cathode. The wave propagation velocity was measured at different points along the tube axis. The wave emission spectrum contains Hg, Ar, and Ar+ lines. The intensities of these lines measured at a fixed point exhibit very different time behaviors. The effect of the tube shielding on the breakdown characteristics was examined. It is found that, at a sufficiently narrow gap between the shield and the tube, this effect can be substantial.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available