4.7 Article Proceedings Paper

Slice-level diffusion encoding for motion and distortion correction

Journal

MEDICAL IMAGE ANALYSIS
Volume 48, Issue -, Pages 214-229

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.media.2018.06.008

Keywords

MRI; Diffusion; Motion correction; Microstructure; Foetal imaging; EPI

Funding

  1. European Research Council under the European Union Seventh Framework Programme/ERC [319456]
  2. NIH Human Placenta Project [1U01HD087202-01]
  3. Wellcome Trust [201374/Z/16/Z]
  4. Wellcome EPSRC Centre for Medical Engineering at Kings College London [WT 203148/Z/16/Z]
  5. MRC strategic grant [MR/K006355/1]
  6. National Institute for Health Research (NIHR) Biomedical Research Centre based at Guys and St Thomas NHS Foundation Trust
  7. Kings College London
  8. MRC [MR/K006355/1] Funding Source: UKRI
  9. Wellcome Trust [201374/Z/16/Z] Funding Source: Wellcome Trust

Ask authors/readers for more resources

Advances in microstructural modelling are leading to growing requirements on diffusion MRI acquisitions, namely sensitivity to smaller structures and better resolution of the geometric orientations. The resulting acquisitions contain highly attenuated images that present particular challenges when there is motion and geometric distortion. This study proposes to address these challenges by breaking with the conventional one-volume-one-encoding paradigm employed in conventional diffusion imaging using single-shot Echo Planar Imaging. By enabling free choice of the diffusion encoding on the slice level, a higher temporal sampling of slices with low b-value can be achieved. These allow more robust motion correction, and in combination with a second reversed phase-encoded echo, also dynamic distortion correction. These proposed advances are validated on phantom and adult experiments and employed in a study of eight foetal subjects. Equivalence in obtained diffusion quantities with the conventional method is demonstrated as well as benefits in distortion and motion correction. The resulting capability can be combined with any acquisition parameters including multiband imaging and allows application to diffusion MRI studies in general. (C) 2018 The Authors. Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available