4.2 Article

Reference values for circulating pregnancy-associated microRNAs in maternal plasma and their clinical usefulness in uncomplicated pregnancy and hypertensive disorder of pregnancy

Journal

JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH
Volume 44, Issue 5, Pages 840-851

Publisher

WILEY
DOI: 10.1111/jog.13610

Keywords

biological marker; maternal plasma; obstetric management; pregnancy-associated placental microRNA; reference value

Funding

  1. Japan Society for the Promotion of Science KAKENHI [16K1570, 17K11241, 17K16302, 16K11144, 15K10677, 17K11283]
  2. Grants-in-Aid for Scientific Research [17K11241, 16K15710, 17K11283, 16K11144, 17K16302, 15K10677] Funding Source: KAKEN

Ask authors/readers for more resources

Aim: The aim of this study was to establish the reference values for circulating pregnancy-associated placental microRNAs in maternal plasma and clarify their clinical significance in patients with hypertensive disorder of pregnancy (HDP). Methods: Blood samples were collected from 145 women with uncomplicated pregnancies (24, 26, 31 and 32 women at 12, 23, 30 and 36 weeks of gestation, respectively, and 32 women 1 day after delivery). Plasma concentrations of pregnancy-associated placental microRNAs (miR-515-3p, miR-517a, miR-517c and miR-518b) were measured by quantitative real-time reverse-transcription polymerase chain reaction. Reference values for each microRNA were determined by the line of best fit and 95% prediction interval and are expressed as logarithmic transformation. To clarify the clinical significance of these reference values, we measured the plasma concentrations of pregnancy-associated microRNAs in a different population comprising 33 pregnant women with HDP and 44 women with uncomplicated pregnancies. Results: Reference values for circulating pregnancy-associated placental microRNAs on chromosome 19 miRNA clusters showed an increasing tendency as pregnancy progressed and decreased significantly 1 day after delivery (P < 0.05). The sensitivity and specificity of each reference value were 57.6% and 93.2% for miR-515-3p, 63.6% and 75.0% for miR-517a, 75.8% and 79.5% for miR-517c and 63.6% and 75.0% for miR-518b, respectively. The positive and negative predictive values of each reference value were 86.4% and 74.5% for miR-515-3p, 65.6% and 73.3% for miR-517a, 73.5% and 81.4% for miR-517c and 65.6% and 73.3% for miR-518b, respectively. Conclusion: Establishing the reference values for circulating pregnancy-associated placental microRNAs in maternal plasma could be useful for the evaluation of HDP.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available