4.3 Article

Multiple frequency saturation pulses reduce CEST acquisition time for quantifying conformational exchange in biomolecules

Journal

JOURNAL OF BIOMOLECULAR NMR
Volume 71, Issue 1, Pages 19-30

Publisher

SPRINGER
DOI: 10.1007/s10858-018-0186-1

Keywords

Solution NMR; CEST; Sensitivity enhancement; Fast data acquisition; Proteins

Funding

  1. NSF award MCB [1506420]
  2. NIH [R01 EB016045, R01 AI108889, GM 117118, F99 CA212474, OD016343]
  3. Dean's Dissertation Fellowship from New York University

Ask authors/readers for more resources

Exchange between conformational states is required for biomolecular catalysis, allostery, and folding. A variety of NMR experiments have been developed to quantify motional regimes ranging from nanoseconds to seconds. In this work, we describe an approach to speed up the acquisition of chemical exchange saturation transfer (CEST) experiments that are commonly used to probe millisecond to second conformational exchange in proteins and nucleic acids. The standard approach is to obtain CEST datasets through the acquisition of a series of 2D correlation spectra where each experiment utilizes a single saturation frequency to H-1, N-15 or C-13. These pseudo 3D datasets are time consuming to collect and are further lengthened by reduced signal to noise stemming from the long saturation pulse. In this article, we show how usage of a multiple frequency saturation pulse (i.e., MF-CEST) changes the nature of data collection from series to parallel, and thus decreases the total acquisition time by an integer factor corresponding to the number of frequencies in the pulse. We demonstrate the applicability of MF-CEST on a Src homology 2 (SH2) domain from phospholipase C gamma and the secondary active transport protein EmrE as model systems by collecting C-13 methyl and N-15 backbone datasets. MF-CEST can also be extended to additional sites within proteins and nucleic acids. The only notable drawback of MF-CEST as applied to backbone N-15 experiments occurs when a large chemical shift difference between the major and minor populations is present (typically greater than similar to 8 ppm). In these cases, ambiguity may arise between the chemical shift of the minor population and the multiple frequency saturation pulse. Nevertheless, this drawback does not occur for methyl group MF-CEST experiments or in cases where somewhat smaller chemical shift differences occur are present.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available