Background and Aims: Reports on the performance of unsedated ultrathin endoscopy via the transnasal (uTNE) and transoral (uTOE) routes are conflicting. We aimed to estimate the technical success rate, patient preference, and acceptability of uTNE and uTOE alone and in comparison with conventional EGD (cEGD; with or without sedation). Methods: A systematic review and meta-analysis was performed on all primary studies reporting the outcomes of interest. Electronic databases (Cochrane library, MEDLINE, EMBASE) were searched on February 1, 2014. Results: Thirty-four studies met the inclusion criteria with 6659 patients in total. The pooled technical success rate was 94.0% for uTNE (95% confidence interval [CI], 91.6-95.8; 30 studies) and 97.8% for uTOE (95% CI, 95.6-98.9; 16 studies). The difference in proportion of success for uTNE compared with cEGD was -2.0% (95% CI, -4.0 to -1.0; 18 studies), but that difference was not significant when uTNE < 5.9 mm in diameter was used (-1.0%; 95% CI, -3.0 to.0; 9 studies). There was no significant difference in success rate between uTOE and cEGD (. 0%; 95% CI, -1.0 to 2.0; 10 studies). The pooled difference in proportion of patients who preferred uTNE over cEGD was 63.0% (95% CI, 49.0-76.0; 10 studies), whereas preference for uTOE versus cEGD was not significantly different (38.0%; 95% CI, -4.0 to 80.0; 2 studies). Acceptability was high for both uTNE (85.2%; 95% CI, 79.1-89.9; 16 studies) and uTOE (88.7%; 95% CI, 82.4-92.9; 10 studies). Conclusions: Technical success rate for uTNE < 5.9 mm is equivalent to cEGD. uTNE has high patient acceptability, with better patient preference, and therefore could be a useful alternative to cEGD for screening purposes. uTOE had a similar technical success rate but an equivocal preference to cEGD.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available