4.4 Article

MOPSO/FDMT-based Pareto-optimal solution for coordination of overcurrent relays in interconnected networks and multi-DER microgrids

Journal

IET GENERATION TRANSMISSION & DISTRIBUTION
Volume 12, Issue 12, Pages 2871-2886

Publisher

INST ENGINEERING TECHNOLOGY-IET
DOI: 10.1049/iet-gtd.2018.0079

Keywords

Pareto optimisation; overcurrent protection; relay protection; power system interconnection; distributed power generation; particle swarm optimisation; decision making; fuzzy set theory; minimisation; power generation faults; fault diagnosis; MOPSO; FDMT-based Pareto-optimal solution; overcurrent relay coordination algorithm; interconnected network; multiDER microgrid; discrimination time minimisation; OC relay coordination algorithm; power system relay coordination; optimal operation time; OT; single-objective optimisation algorithm; multiobjective particle swarm optimisation algorithm; fuzzy decision-making tool; IEC-6090 standard; fault calculation; distributed energy resource

Ask authors/readers for more resources

The minimisation of discrimination time between main and backup overcurrent (OC) relays is one of the most important issues in power system relays coordination. On account of the massive computation burden and complexities for determining power system breakpoint, the implementation of the previously reported OC protection methods in large interconnected networks is almost impossible or at least cumbersome. In this regard, a variety of optimisation algorithms have been presented for coordination between relays and finding optimal operation time (OT) of the protection system. The previously reported single-objective optimisation algorithms have some limitations/drawbacks regarding OT of relays and their coordination. In this study, a new multi-objective optimisation algorithm is presented for coordination of OC relays in interconnected networks, based on multi-objective particle swarm optimisation (MOPSO) and fuzzy decision-making tool (FDMT). Then, using some useful assumption and recommendations of IEC-6090 and fault calculations for the microgrids including distributed energy resources, the proposed method is generalised for OC relay coordination in microgrids. Finally, the proposed method has been successfully implemented on different test systems and the obtained results have been compared with other reported methods to prove accuracy, authenticity, and efficiency of the MOPSO/FDMT-based protection and relay coordination algorithm.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available