Journal
COLLOIDS AND SURFACES B-BIOINTERFACES
Volume 165, Issue -, Pages 229-234Publisher
ELSEVIER SCIENCE BV
DOI: 10.1016/j.colsurfb.2018.02.018
Keywords
Contact lenses; Atomic force microscopy; Roughness; Topography
Ask authors/readers for more resources
In the paper the results of AFM surface profile measurements of seven new long-wear contact lenses (CL) available in Poland are presented. Calculated statistical roughness parameters are shown, namely standard deviation (RMS), mean roughness, maximum difference between peak and valley, skewness, and kurtosis. It is demonstrated that CLs manufactured using recent methods, such as two-stage polimerisation or extending silicon chains exhibit small RMS, less than 10 nm, in comparison with older generation CLs which maintains RMS on the level of tens of nanometers. Then, a comparison of results obtained using a typical silicon tip and a silicon tip covered with alkylsilane is also demonstrated. As a result, roughness parameters, such as RMS, are higher for the case of alkylsilane-coated tip than for a typical silicon tip, 8.39 +/- 0.16 nm vs. 6.22 +/- 0.9 nm, which leads to the conclusion that the proper choice of the tip material significantly influences the outcome of the experiment. Finally, the reliability and limits of such measurements are discussed. (C) 2018 Elsevier B.V. All rights reserved.