4.8 Article

Multi-parametric rigid and flexible, low-cost, disposable sensing platforms for biomedical applications

Journal

BIOSENSORS & BIOELECTRONICS
Volume 102, Issue -, Pages 668-675

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2017.10.038

Keywords

PCB electrode; Ion sensors; Flexible; Multi-parametric; Potentiometric sensors

Funding

  1. UK Engineering and Physical Sciences Research Council (EPSRC) [EP/L014149/1]
  2. EPSRC [EP/L014149/1, EP/J021199/1] Funding Source: UKRI
  3. Engineering and Physical Sciences Research Council [EP/J021199/1, EP/L014149/1] Funding Source: researchfish

Ask authors/readers for more resources

The measurement of Na+, K+ and H+ is essential in medicine and plays an important role in the assessment of tissue ischemia. Microfabrication, inkjet- and screen-printing can be used for solid contact ion selective electrodes (ISE) realization; these, however, can be non-standardized, costly and time consuming processes. We present the realization of ISEs on post-processed electrodes fabricated via standardized printed circuit board (PCB) manufacturing techniques. In vitro results are presented from two rigid platforms (32 ISEs) for liquid sample dip-stick measurements and two flexible platforms (6 and 32 ISEs) for post-surgical intestinal tissue monitoring, each with a common reference electrode (RE). These are combined with optimized tetrapolar bioimpedance sensors for tissue ischemia detection. Both electroless and hard gold PCB finishes are examined. Apart from the electroless rigid platform, the rest demonstrated comparable and superior performance, with the pH sensors demonstrating the greatest deviation; the flexible hard gold platform achieved a sensitivity 4.6 mV/pH and 49.2 mV/pH greater than the electroless flexible and rigid platforms, respectively. The best overall performance was achieved with the hard gold flexible platform with sensitivities as large as 73.4 mV/pH, 56.3 mV/log [Na+], and 57.4 mV/log [K+] vs. custom REs on the same substrate. Simultaneous measurement of target analytes is demonstrated with test solutions and saliva samples. The results demonstrate superior performance to other PCB-based pH sensors and Na+ and K+ PCB-based sensors with comparable performance to potentiometric sensors fabricated with other techniques, paving the way towards mass-produced, low-cost, disposable, multi-parametric chemical sensing diagnostic platforms.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available