4.8 Article

Double determination of long noncoding RNAs from lung cancer via multi-amplified electrochemical genosensor at sub-femtomole level

Journal

BIOSENSORS & BIOELECTRONICS
Volume 113, Issue -, Pages 116-123

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2018.04.062

Keywords

Dual signal detection; Long noncoding RNA; Multiplexed amplification; Enzyme-aided target recycling; Hybridization chain reaction; Electrochemical genosensor

Funding

  1. National Natural Science Foundation of China [21575064]
  2. Natural Science Foundation of Jiangsu Province [BK20151535]
  3. Six Talent Peaks Project in Jiangsu Province [2016-SWYY-022]
  4. Qinlan Project of Jiangsu Education Department
  5. Program for Innovative Research Team in Universities of Jiangsu Province

Ask authors/readers for more resources

An ultrasensitive electrochemical genosensor has been fabricated for the double determination of two different specific sequences deduced from the maternally expressed gene3 (MEG3) IncRNA (long noncoding RNA), which was demonstrated by coupling RNase A-aided target recycling with DNA supersandwich-induced signal enhancement, based on a composite interface of graphene-like tungsten disulfide/dendritic gold nanostructures (WS2/DGN). Firstly, duple target sequences of T-1 and T-2 were captured by the primer probes of P-1/P-2 functionalized Fe3O4@C magnetic nanoparticles, via the DNA/RNA hybridization between T-1/T-2 and P-1/P-2. In the presence of RNase A, T-1 and T-2 were released to trigger the target recycling, accompanied by the generation of numerous intermediate DNAs designated as IT1 and IT2, respectively. After the magnetic separation, the IT1 and IT2 were liberated and hybridized with the capture probes of CP1/CP2 loaded DGN/WS2 modified electrode. Subsequently, the stepwise DNA hybridization chain reactions (HCR) labeled with ferrocene (Fc) and methyleneblue (MB) were processed, respectively. The DPV current values of Fc and MB were recorded, which were proportional with the concentration of T-1 and T-2, respectively. Using the multiplexed amplification strategy, this newly designed genosensor provided a wide linear range from 1 fM to 100 pM with a low detection limit of 0.25 fM for T-1 and 0.3 fM for T-2. The application of the genosensor in real serum sample has also been studied, confirming the excellent selectivity and sensitivity for the application in bioanalysis and clinical diagnostics.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available