Impact of Cosmetics on the Surface Properties of Silicone Hydrogel Contact Lenses

Journal

EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE
Volume 41, Issue 4, Pages 228-235

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/ICL.0000000000000101

Keywords

-

Categories

Funding

  1. Alcon Research Ltd.
  2. Advanced Vision Research
  3. Alcon
  4. AlgiPharma
  5. Allergan
  6. AMO
  7. Bausch Lomb
  8. CooperVision
  9. Essilor
  10. Johnson & Johnson Vision Care, Inc.
  11. Oculus
  12. Ocusense
  13. Sauflon
  14. TearScience
  15. Visioneering Technologies

Ask authors/readers for more resources

Purpose: This study evaluated the impact of various cosmetics on the surface properties of silicone hydrogel (SiHy) contact lens materials. Methods: In this in vitro experiment, 7 SiHy contact lens materials were coated with 1 of 9 cosmetics, including common hand creams (3), eye makeup removers (3), and mascaras (3). Dark-field microscopy images were taken to determine pixel brightness (PB) after cosmetic exposure, which describes the visible surface deposition (n=6 for each lens type), with a higher PB indicating increased deposition. The sessile drop technique was used to determine the advancing contact angle (CA). Measurements were repeated for both methods after a single peroxide-based cleaning cycle. Results: Pixel brightness was significantly higher for mascara-coated lenses compared with the other cosmetic products (P<0.01). The peroxide-based lens care solution removed most deposits from the nonwaterproof mascara for 4 lens types, whereas deposits remained relatively unchanged for 1 waterproof mascara (P>0.05). Hand creams and makeup remover had minimal impact on PB. Changes in CA measurements after cosmetic application were highly lens dependent. Hand creams caused primarily a decrease in CA for 5 of the 7 lens types, whereas 1 of the waterproof mascaras caused a significant increase of 30 to 50 degrees for 3 lens types. Conclusion: Some mascara-lens combinations resulted in increased CA and PB, which could have an impact on in vivo lens performance. Nonwaterproof mascara was mostly removed after a cleaning cycle. Further research is needed to understand the clinical implications for SiHy lens wearers using cosmetics.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available