4.6 Article

A gold immunochromatographic assay for simultaneous detection of parathion and triazophos in agricultural products

Journal

ANALYTICAL METHODS
Volume 10, Issue 4, Pages 422-428

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c7ay02481a

Keywords

-

Funding

  1. Ministry of Science and Technology of people's Republic of China [2016YFD0200803-3]
  2. Department of Finance of Jiangsu Province [CX (17) 1003]
  3. Department of Science and Technology of Jiangsu Province [BE2014722]

Ask authors/readers for more resources

A multi-component gold immunochromatographic assay (GICA) was developed for the rapid and simultaneous detection of parathion and triazophos in agricultural products. Two different antigens were immobilized separately in two test lines on a nitrocellulose membrane, and two specific monoclonal antibodies (McAbs) against parathion and triazophos were labeled with colloidal gold nanoparticles (AuNPs) as detection probes, respectively. After optimization, the visual cut-off limits of detection for the strip test were 0.05 mu g mL(-1) for triazophos and 0.1 mu g mL(-1) for parathion. Thereafter, the developed GICA strip was employed and evaluated for the real sample test using spiked agricultural products (rice, vegetable and fruit samples). The results showed that matrix interference was negligible and the qualification was in good agreement with the results of gas chromatography (GC). The rapid, simple and low cost multidetection sensor could be a potential alternative format for on-site and rapid simultaneous detection of parathion and triazophos.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
Article Chemistry, Analytical

Magnetic mesoporous Fe3O4@nSiO2@mSiO2 nanoparticles for high-throughput mass spectrometry detection of hydrolyzed products of organophosphorus nerve agents

Gang Qu, Yuxin Zhao, Qiaoli Zhang, Jina Wu, Xiaosen Li, Yang Yang, Shilei Liu

Summary: In this study, magnetic mesoporous materials combined with real-time in situ mass spectrometry were used for the high-throughput detection of hydrolyzed products of organophosphorus nerve agents. The method showed good linearity, low limits of detection and quantification, and high extraction recoveries. The magnetic preparation method used was quick, cost-effective, rugged, and safe. The results demonstrated the potential of this method for rapid and efficient determination of the target analytes in environmental samples.

ANALYTICAL METHODS (2024)

Article Chemistry, Analytical

Voltammetric methods for electrochemical characterization and quantification of artemether-based antimalarials

Anna Hildebrand, Mariam Merchant, Danny O'Hare

Summary: Substandard and falsified artemisinin derivatives in antimalarials have caused significant deaths and economic losses. This study evaluates the feasibility of voltammetric methods for identifying and quantifying artemether. The findings suggest that electrochemical analysis shows promise as a method for artemether identification and quantification.

ANALYTICAL METHODS (2024)

Article Chemistry, Analytical

An impedimetric immunosensor for diagnosis of Brazilian spotted fever in blood plasma

Marx Osorio Araujo Pereira, Alvaro Ferreira Junior, Edson Silvio Batista Rodrigues, Helena Mulser, Giovanna Nascimento de Mello e Silva, Wallans Torres Pio dos Santos, Eric de Souza Gil

Summary: Brazilian spotted fever (BSF) is a serious and rapidly evolving disease. A new impedimetric immunosensor was developed for rapid diagnosis by measuring specific antibodies in plasma. The sensor demonstrated selectivity and accuracy, and has potential for important applications in diagnostic testing.

ANALYTICAL METHODS (2024)

Article Chemistry, Analytical

Method validation for (ultra)-trace element concentrations in urine for small sample volumes in large epidemiological studies: application to the population-based epidemiological multi-ethnic study of atherosclerosis (MESA)

Kathrin Schilling, Ronald A. Glabonjat, Olgica Balac, Marta Galvez-Fernandez, Arce Domingo-Relloso, Vesna Slavkovich, Jeff Goldsmith, Miranda R. Jones, Tiffany R. Sanchez, Ana Navas-Acien

Summary: Analysis of trace elements in urine is an important tool for assessing exposures, diagnosing nutritional status, and guiding public health and healthcare intervention. This study provides a sensitive method for analyzing 18 elements in urine samples, using only 100 μL. The results show good accuracy and sensitivity of the method.

ANALYTICAL METHODS (2024)

Article Chemistry, Analytical

Selective purification and rapid quantitative detection of spores using a stepped magnetic flow device

Mengya Li, Shijie Liu, Shiliang Guo, Dong Liang, Miaoyun Li, Yaodi Zhu, Lijun Zhao, Jong-Hoon Lee, Gaiming Zhao, Yangyang Ma, Yanxia Liu

Summary: In this study, a magnetic flow device was developed to purify spores in a culture medium system. The device used magnetic nanoparticles to absorb vegetative cells, separating them from the spores. The achieved purity of the collected spores was over 95%. The study also demonstrated a rapid quantitative detection method using Raman spectroscopy.

ANALYTICAL METHODS (2024)

Article Chemistry, Analytical

Construction of a molecularly imprinted fluorescent sensor based on an amphiphilic block copolymer-metal-organic framework for the detection of oxytetracycline in milk

Wanqiong Liu, Zixuan Wu, Jianwei Peng, Zebin Xu, Yong Liang

Summary: Metal-organic frameworks (MOFs) are effective carriers for molecular imprinting, but their poor dispersibility in aqueous solution is a significant drawback. In this study, we have applied amphiphilic block copolymers and molecularly imprinted technology on MOFs to improve the hydrophilicity of molecularly imprinted fluorescent materials.

ANALYTICAL METHODS (2024)